Thawj thiab theem nrab Calibration ntawm pH Meter
Ib qho point calibration ntawm pH meter:
Txhua lub pH ntsuas yuav tsum tau ntsuas nrog pH tus qauv daws ua ntej ntsuas pH tus nqi ntawm tus qauv. Rau cov qauv nrog qhov ntsuas qhov tseeb ntawm 0.1 lossis qis dua pH, txoj kev ntsuas ntsuas tuaj yeem siv los kho qhov ntsuas. Feem ntau, pH =6.86 lossis pH =7.00 tus qauv tsis haum yog xaiv. Qee cov twj paj nruag tsuas muaj pH ntawm 0.2 lossis 0.1, yog li lawv tsuas muaj ib qho kev hloov kho qhov rooj. Kev ua haujlwm tshwj xeeb
cov kauj ruam yog raws li nram no:
(1) Ntsuas qhov ntsuas kub ntawm cov txheej txheem kev daws teeb meem, kos lub rooj los txiav txim siab tus nqi pH ntawm qhov ntsuas kub ntawd, thiab kho qhov kub hloov kho qhov ntsuas kub rau qhov kub ntawd;
(2) Yaug cov electrode nrog dej ntshiab thiab co kom qhuav;
(3) Muab cov electrode tso rau hauv cov tshuaj tsis haum thiab co nws, ces muab tso rau hauv. Tom qab kev nyeem ntawv ruaj khov, kho qhov chaw qhov rooj kom lub ntsuas ntsuas pH tus nqi ntawm cov qauv kev daws teeb meem;
(4) Tshem tawm cov electrode, yaug thiab kiv kom qhuav;
(5) Ntsuas qhov ntsuas kub ntawm tus qauv thiab kho cov pH ntsuas kub ntsuas qhov ntsuas kub rau qhov ntsuas kub;
(6) Muab cov electrode tso rau hauv cov qauv kev daws teeb meem, co nws thiab cia nws sawv ntsug. Tom qab cov zaub stabilizes, nyeem ntawv.
Ob lub ntsiab lus calibration ntawm pH meter:
Rau precision pH meters, nyob rau hauv tas li ntawd mus rau "txoj hauj lwm" thiab "kub them nyiaj" kev hloov kho, kuj muaj ib tug electrode "txoj kab nqes" hloov, uas yuav tsum tau calibration nrog ob tug txheej txheem tsis daws teeb meem. Feem ntau, pH 6.86 los yog pH 7.00 yog siv rau "txoj hauj lwm" calibration, thiab ces pH 4.00 (acidic) los yog pH 9.18 los yog pH 10.01 (alkaline) buffer tov yog xaiv rau "txoj kab nqes kho" raws li acidity thiab alkalinity ntawm cov tshuaj tov. Cov kauj ruam tshwj xeeb yog raws li nram no:
(1) Ntxuav thiab kiv kom qhuav cov electrode electrode, muab tso rau hauv ib qho kev daws teeb meem nrog pH =6.86 lossis pH =7.00, thiab muab qhov kub thiab qhov kub ntawm qhov kev daws teeb meem. Tom qab tus nqi qhia tau ruaj khov, kho qhov chaw qhov rooj kom qhov ntsuas qhov ntsuas pH yog tus nqi ntawm cov qauv kev daws teeb meem.
(2) Tshem tawm cov electrode, ntxuav thiab tig kom qhuav, thiab muab tso rau hauv cov txheej txheem thib ob. Tom qab tus nqi qhia tau ruaj khov, kho txoj kab nqes pob qhov ntsuas ntawm qhov ntsuas kom tus nqi qhia ntawm qhov ntsuas yog pH tus nqi ntawm cov txheej txheem thib ob.
(3) Ntxuav thiab tig kom qhuav cov electrode electrode, ces muab tso rau hauv cov txheej txheem tov nrog pH 6.86 los yog pH 7.00. Yog tias qhov ua yuam kev dhau 0.02 pH, rov ua cov kauj ruam (1) thiab (2). Kom txog rau thaum tus nqi pH raug tso tawm tuaj yeem pom yam tsis tau kho lub pob qhov rooj hauv ob qho kev daws teeb meem.
(4) Tshem tawm cov electrode, ntxuav nws thiab co kom qhuav. Kho qhov pH kub them pob qhov rooj rau qhov ntsuas kub. Muab cov electrode tso rau hauv cov qauv kev daws teeb meem, co nws, thiab cia nws sawv ntsug. Tom qab cov zaub stabilizes, nyeem ntawv.