1, Calibration method

Tig lub hwj chim hloov ntawm lub ntsuas, tig qhov ntsuas kev ntsuas mus rau "PH" txoj hauj lwm, ua ntej ntxuav cov electrode nrog dej distilled, ces ntxig cov electrode rau hauv cov tshuaj tsis nrog PH=7, kho qhov "kub" compensator kom qhov ntsuas kub yog tib yam li qhov kub thiab txias ntawm cov tshuaj, thiab tom qab ntawd kho tus nqi PH uas qhia los ntawm "txoj hauj lwm ntawm PH" raws li tus nqi regulator. kub. Tom qab ntawd tshem tawm cov electrode tso rau hauv PH7 tsis muaj tshuaj thiab ntxuav nws nrog dej distilled. Ntxig lub electrode ntxuav rau hauv cov tshuaj tsis nrog pH tus nqi ntawm 4, kom qhov kub thiab txias qhia los ntawm "temperature" compensator ntawm lub ntsuas yog tib yam li qhov kub ntawm cov tshuaj tsis. Tom qab ntawd kho qhov "slope" adjuster kom pH tus nqi tso tawm los ntawm qhov ntsuas tib yam li tus nqi pH ntawm cov tshuaj tsis haum ntawm qhov kub ntawm cov tshuaj. Tom qab calibration, yuav tsum tsis muaj kev hloov pauv ntxiv rau "qhov chaw" thiab "kev nqes hav" adjusters, thiab kev ntsuas pH tam sim no tuaj yeem ua tiav. Tab sis feem ntau, thaum lub tshuab hluav taws xob ntsaws rov qab rau hauv pH ntau ntawm 7, yog tias tus nqi pH tso tawm los ntawm qhov ntsuas yog tib yam li cov tshuaj tsis haum, nws kuj qhia tau tias qhov ntsuas tau raug.

 

Cov kev ceev faj

1. Rov calibrate ntau yam

When there is a significant change in solution temperature compared to the calibration temperature; Electrodes that have been away from the solution for too long; Replaced with a new composite electrode; When there are changes in the "positioning" and "slope" adjusters; After measuring pH>12 los yog pH<2; Measure solutions containing fluoride with acidity below pH 7 or concentrated organic solutions.

 

2. Kev tu cov cuab yeej

Lub tswv yim kawg ntawm qhov ntsuas (piv txwv li cov khoom siv hluav taws xob sib txuas) yuav tsum tau ceev ceev heev; Lub taub hau electrode yog nyias nyias, tsis txhob kov cov khoom tawv kom tiv thaiv kev puas tsuaj ntawm electrode; Muaj cov av ntawm lub taub hau electrode sib xyaw. Siv cov paj rwb kho mob los so lub taub hau electrode los yog ntxuav nws nrog 0.1N dilute hydrochloric acid; Tom qab siv sijhawm ntev, qhov feem pua ​​​​ntawm cov electrode txo qis me ntsis. Qhov kawg ntawm cov electrode yuav tsum tau soaked nyob rau hauv 4% HF rau 3-5 vib nas this, ntxuav nrog distilled dej, soaked nyob rau hauv ib tug 0.1mol / L HCL tov rau ob peb teev, yaug nrog dej deionized los kho nws; Yog hais tias lub taub hau electrode puas tawg los yog muaj hnub nyoog (tom qab khaws cia rau ntau tshaj ob xyoos), yuav tsum tau hloov lub electrode tshiab. Ua ntej siv cov electrode tshiab, tsau nws hauv 3mol / LKCL tov rau 24 teev; Thaum calibrating nrog buffer tov, xyuas kom meej nws kev ntseeg tau; Lub LCD zaub qhia "LOBAT" thiab lub roj teeb yuav tsum tau hloov; Tsis txhob tso lub LCD saib kom ncaj qha tshav ntuj

 

3. Qhov kawg ntawm cov khoom siv (xws li cov khoom siv hluav taws xob sib txuas) yuav tsum tau ceev kom huv si, thiab cov hluav taws xob ntsaws yuav tsum tsis txhob nquag tshem tawm kom tsis txhob muaj plua plav thiab cov av noo nkag mus.

 

4. Lub electrode yuav tsum tau muab tso rau thiab calibrated siv tus txheej txheem buffer tov nrog ib tug paub pH nqi ua ntej siv.

 

5. Tom qab tshem lub hau, yuav tsum ceev faj kom cov iav rhiab hauv cov yas tiv thaiv tsis tuaj yeem tiv nrog cov khoom tawv. Txhua yam kev puas tsuaj los yog khawb yuav ua rau lub electrode ua tsis tiav.

 

6. Tom qab kev ntsuas tiav lawm, yuav tsum muab lub hau tiv thaiv, thiab ib qho me me ntawm cov kua ntxiv (3M / mol KCL) yuav tsum muab tso rau hauv lub hau kom cov electrode npuas moist.

 

7. Cov hlau lead tawm ntawm qhov kawg ntawm cov electrode yuav tsum tau ua kom huv si thiab qhuav kom tsis txhob luv luv ntawm ob qho kawg ntawm cov zis, txwv tsis pub nws yuav ua rau qhov ntsuas tsis raug lossis tsis raug.

 

8. Tsis txhob muab tso rau hauv cov dej distilled los yog cov protein ntau thiab cov kua qaub fluoride, thiab tiv thaiv kev sib cuag nrog cov roj silicone.

 