Lub ntsiab lus ntawm txhua qhov ntsuas ntawm Digital Multimeter

May 18, 2023

Tso lus

Lub ntsiab lus ntawm txhua qhov ntsuas ntawm digital multimeter

 

Qhov tseeb (precision) kev daws teeb meem (kev daws teeb meem) ntsuas ntau yam, 3 thiab 1/2 piav qhia txog cov ntsuas digital multimeter, nws txhais li cas?


Lub npe 3 thiab 1/2 digital multimeter tuaj yeem tso saib 0000-1999. Thawj tus lej tsuas tuaj yeem tso saib 1 lossis 0, 3 sawv cev rau cov, kaum, thiab ntau pua tuaj yeem tso saib tus lej ntawm 0-9, thiab 1/2 sawv cev rau ntau txhiab Tsuas yog 0 thiab 1 tuaj yeem tso tawm . Nyeem nws li "peb thiab ib nrab". Xws li cov hnab tshos digital multimeters suav nrog DT830A, DT830C, DT890D thiab lwm yam.


Cov lej tso saib ntawm ib qho digital multimeter feem ntau yog {{0}}/2 rau 8 1/2 tus lej. Muaj ob lub hauv paus ntsiab lus rau kev txiav txim cov lej ntawm cov cuab yeej digital: ib qho yog tias cov lej uas tuaj yeem pom txhua tus lej ntawm 0 mus rau 9 yog tus lej lej; yog tus lej, thiab suav tus nqi yog 2000 thaum siv tag nrho cov nplai, uas qhia tau hais tias qhov ntsuas muaj 3 tus lej lej, thiab tus lej ntawm tus lej yog 1, thiab tus denominator yog 2, yog li nws yog hu ua 3 1/2 tus lej, nyeem raws li "peb thiab ib nrab tus lej", qhov siab tshaj plaws tsuas tuaj yeem tso saib 0 lossis 1 (0 feem ntau tsis pom). 3 2/3 tus lej (hais tias "peb thiab ob feem peb tus lej") Tus lej siab tshaj plaws ntawm lub tshuab ntsuas digital tsuas tuaj yeem tso saib tus lej ntawm 0 txog 2, yog li qhov siab tshaj plaws ntawm cov zaub yog ± 2999. Raws li cov xwm txheej zoo ib yam, nws yog 50 feem pua ​​​​siab tshaj qhov txwv ntawm 3 1 / 2 tus lej digital multimeter, uas yog qhov tseem ceeb tshwj xeeb tshaj yog thaum ntsuas 380V AC voltage.


Piv txwv li, thaum ntsuas kab hluav taws xob hluav taws xob nrog digital multimeter, tus lej siab tshaj plaws ntawm tus lej zoo tib yam {{0}}}/2-digit digital multimeter tsuas yog 0 lossis 1. Yog tias koj xav tau ntsuas 220V lossis 380V daim phiaj hluav taws xob, koj tsuas tuaj yeem siv peb tus lej los tso saib nws. tu 1v. Nyob rau hauv sib piv, siv ib tug 3 3/4-digit digital multimeter los ntsuas cov kab hluav taws xob voltage, tus lej siab tshaj tuaj yeem tso tawm 0 txog 3, kom nws tuaj yeem tso tawm plaub tus lej nrog kev daws teeb meem ntawm 0.1V, uas txawv ntawm 4 1/2-digit digital multimeter. tib zog.


Nrov digital multimeters feem ntau yog cov khoom siv tes tuav nrog 3 1/2 tus lej zaub, thiab 4 1/2 thiab 5 1/2 tus lej (hauv qab 6 tus lej) digital multimeters muab faib ua ob hom : handheld thiab desktop. Ntau tshaj 6 1/2 tus lej feem ntau yog cov khoom siv digital multimeters.


Lub multimeter digital tau txais cov thev naus laus zis thev naus laus zis thev naus laus zis, nrog cov duab pom tseeb thiab nkag siab thiab nyeem tau raug. Nws tsis tsuas yog ua kom lub hom phiaj ntawm kev nyeem ntawv, tab sis kuj ua raws li tib neeg txoj kev nyeem ntawv, thiab tuaj yeem ua kom luv luv nyeem ntawv lossis kaw lub sijhawm. Cov txiaj ntsig no tsis muaj nyob rau hauv cov tshuaj analog (piv txwv li pointer) multimeters.


1. Qhov tseeb (precision)
Qhov tseeb ntawm digital multimeter yog kev sib xyaw ua ke ntawm cov txheej txheem thiab qhov tsis raug hauv qhov ntsuas ntsuas. Nws qhia txog qib kev pom zoo ntawm tus nqi ntsuas thiab tus nqi tseeb, thiab tseem qhia txog qhov loj ntawm qhov ntsuas qhov yuam kev. Feem ntau hais lus, qhov siab dua qhov tseeb, qhov me me ntawm qhov ntsuas qhov yuam kev, thiab rov ua dua.


Muaj peb txoj hauv kev los qhia qhov tseeb, uas yog raws li hauv qab no:


Qhov tseeb=±(ib feem RDG ntxiv rau b feem pua ​​FS ) ( 2.2.1 )


Qhov tseeb=±(ib feem RDG ntxiv rau n cov lus) ( 2.2.2 )


Qhov tseeb=±(ib feem pua ​​​​RDG ntxiv rau b feem pua ​​​​FS ntxiv rau n cov lus) ( 2.2.3 )


Nyob rau hauv cov mis (2.2.1), RDG yog tus nqi nyeem ntawv (uas yog, tus nqi zaub), FS sawv cev rau tus nqi tag nrho, thiab cov khoom dhau los hauv cov brackets sawv cev rau A/D converter thiab functional converter (xws li voltage divider, shunt, qhov tseeb zoo tus nqi converter) thiab lub sij hawm tom kawg yog qhov yuam kev vim digitization. Hauv cov mis (2.2.2), n yog tus nqi ntawm kev hloov pauv hauv tus lej kawg ntawm qhov yuam kev quantization. Yog tias qhov yuam kev ntawm n cov lus hloov mus rau hauv feem pua ​​​​ntawm tag nrho cov nplai, nws dhau los ua tus qauv (2.2.1). Formula (2.2.3) yog qhov tshwj xeeb. Qee cov tuam txhab siv cov lus qhia no, thiab ib qho ntawm ob yam khoom kawg no sawv cev rau qhov yuam kev qhia los ntawm lwm qhov chaw lossis kev ua haujlwm.


Digital multimeters yog qhov tseeb dua li analog analog multimeters. Ua qhov tseeb qhov ntsuas ntawm qhov yooj yim rau kev ntsuas DC voltage ua piv txwv, nws tuaj yeem ncav cuag ± {{{0}}.5 feem pua ​​​​rau 3.5 tus lej, 0.03 feem pua ​​​​rau 4.5 tus lej, thiab lwm yam. Piv txwv: OI857 thiab OI859CF multimeters . Qhov tseeb ntawm multimeter yog qhov taw qhia tseem ceeb heev. Nws qhia txog qhov zoo thiab kev muaj peev xwm ntawm multimeter. Nws yog ib qho nyuaj rau ib tug multimeter nrog cov neeg tsis zoo los qhia tus nqi tiag tiag, uas yuav yooj yim ua rau kev txiav txim siab tsis zoo hauv kev ntsuas.


2. Kev daws teeb meem (kev daws teeb meem)
Tus nqi hluav taws xob sib raug rau tus lej kawg ntawm cov digital multimeter ntawm qhov qis tshaj qhov voltage yog hu ua kev daws teeb meem, uas qhia txog qhov rhiab heev ntawm lub 'meter'. Qhov kev daws teeb meem ntawm cov cuab yeej digital digital nce nrog kev nce ntawm cov lej tso saib. Cov kev daws teeb meem siab tshaj plaws uas cov multimeters digital nrog cov lej sib txawv tuaj yeem ua tiav yog qhov sib txawv, piv txwv li: 100μV rau 3 1/2 tus lej multimeters.


Qhov kev daws teeb meem ntawm digital multimeter kuj tuaj yeem pom los ntawm kev daws teeb meem. Kev daws teeb meem yog qhov feem pua ​​​​ntawm tus lej tsawg tshaj plaws (tshwj tsis yog xoom) uas lub ntsuas ntsuas tuaj yeem tso rau tus lej loj tshaj plaws. Piv txwv li, tus lej tsawg kawg nkaus uas tuaj yeem tshwm sim los ntawm qhov dav dav {{{0}}}/2- tus lej digital multimeter yog 1, thiab tus lej siab tshaj plaws tuaj yeem yog 1999, yog li qhov kev daws teeb meem sib npaug li 1 / 1999 ≈ 0.05 feem pua.


Nws yuav tsum tau taw qhia tias qhov kev daws teeb meem thiab qhov tseeb yog ob lub ntsiab lus sib txawv. Tus qub cim qhov "rhiab heev" ntawm qhov ntsuas, uas yog, muaj peev xwm "paub" me me voltages; qhov tom kawg qhia txog qhov "qhov tseeb" ntawm kev ntsuas, uas yog, qib ntawm qhov sib xws ntawm qhov ntsuas qhov ntsuas thiab qhov tseeb tus nqi. Tsis muaj kev sib txuas tsim nyog ntawm ob, yog li lawv tsis tuaj yeem tsis meej pem, thiab kev daws teeb meem (lossis kev daws teeb meem) yuav tsum tsis txhob yuam kev rau qhov zoo sib xws. Qhov tseeb yog nyob ntawm qhov kev ua yuam kev loj thiab qhov yuam kev quantization ntawm lub internal A/D converter thiab functional converter ntawm lub ntsuas. Los ntawm qhov kev xav ntawm kev ntsuas, kev daws teeb meem yog qhov ntsuas "virtual" (uas tsis muaj dab tsi cuam tshuam nrog kev ntsuas qhov yuam kev), thiab qhov tseeb yog qhov ntsuas "tiag tiag" (nws txiav txim siab qhov loj ntawm kev ntsuas qhov yuam kev). Yog li ntawd, nws tsis muaj peev xwm ua kom cov naj npawb ntawm cov lej tso saib kom txhim kho qhov kev daws teeb meem ntawm qhov ntsuas.


3. Kev ntsuas ntau
Hauv cov multi-function digital multimeter, cov haujlwm sib txawv muaj lawv cov txiaj ntsig siab tshaj plaws thiab qhov tsawg kawg nkaus uas tuaj yeem ntsuas tau. Piv txwv li: 4 1/2- tus lej multimeter, qhov ntsuas qhov ntsuas ntawm DC voltage ntau yog 0.01mV ~ 1000V.


4. Kev ntsuas tus nqi
Tus naj npawb ntawm lub sij hawm digital multimeter ntsuas qhov ntsuas hluav taws xob ib ob yog hu ua qhov ntsuas ntsuas, thiab nws chav tsev yog "times / s". Nws tsuas yog nyob ntawm tus nqi hloov pauv ntawm A / D converter. Qee lub xov tooj ntawm tes digital multimeters siv lub sijhawm ntsuas los qhia qhov ceev ntawm kev ntsuas. Lub sijhawm yuav tsum ua kom tiav cov txheej txheem ntsuas yog hu ua lub voj voog ntsuas.


Muaj qhov tsis sib xws ntawm qhov ntsuas ntsuas thiab qhov ntsuas qhov tseeb. Feem ntau, qhov siab dua qhov tseeb yog, qhov ntsuas qis dua yog, thiab nws nyuaj rau sib npaug ntawm ob. Txhawm rau daws qhov tsis sib xws, koj tuaj yeem teeb tsa cov lej sib txawv lossis teeb tsa qhov ntsuas nrawm hloov pauv hauv tib lub ntsuas ntsuas: ntxiv cov ntaub ntawv ntsuas nrawm, uas yog siv rau A / D converter nrog qhov ntsuas nrawm dua; Kev txhim kho tus nqi ntsuas, txoj kev no kuj muaj nyob rau tam sim no, thiab tuaj yeem ua tau raws li qhov xav tau ntawm cov neeg siv sib txawv rau kev ntsuas tus nqi.


5. Input impedance
Thaum ntsuas qhov ntsuas hluav taws xob, lub ntsuas yuav tsum muaj qhov siab input impedance, kom qhov tam sim no rub los ntawm Circuit Court nyob rau hauv kev ntsuas me me thaum lub sij hawm ntsuas, uas yuav tsis cuam tshuam rau kev ua hauj lwm ntawm Circuit Court nyob rau hauv kev ntsuam xyuas los yog lub teeb liab qhov chaw, thiab muaj peev xwm. txo qhov kev ntsuas yuam kev. Piv txwv li: Lub input tsis kam ntawm DC voltage ntau ntawm ib tug 3 1/2-digit handheld digital multimeter feem ntau yog 10μΩ. Cov ntaub ntawv AC voltage yog cuam tshuam los ntawm cov input capacitance, thiab nws cov input impedance feem ntau qis dua cov ntaub ntawv DC voltage.


Thaum ntsuas tam sim no, lub ntsuas yuav tsum muaj qhov cuam tshuam qis heev, kom lub zog ntawm lub ntsuas hluav taws xob hauv Circuit Court nyob rau hauv kev sim tuaj yeem raug txo kom ntau li ntau tau tom qab txuas rau hauv Circuit Court hauv kev sim. Hlawv tawm lub 'meter'

 

3 Multimeter 1000v 10a

Xa kev nug