+86-18822802390

Kev sib kis thiab Epi-illumination ntawm Microscopes rau Metallographic Analysis Instruments

Jul 10, 2023

Kev sib kis thiab Epi-illumination ntawm Microscopes rau Metallographic Analysis Instruments

 

Txoj kev teeb pom kev zoo ntawm lub tshuab tsom rau cov cuab yeej ntsuas metallographic feem ntau muab faib ua ob pawg: "transmissive lighting" thiab "episcopic lighting". Cov qub yog tsim rau cov khoom pob tshab lossis cov khoom siv translucent, thiab feem ntau ntawm cov khoom siv roj ntsha muaj nyob rau hom teeb pom kev zoo no; tom kawg yog tsim rau cov khoom tsis yog pob tshab, thiab lub teeb ci los ntawm saum toj no, kuj hu ua "reflective lighting". Cov ntawv thov tseem ceeb nrog metallographic microscopy lossis fluorescence microscopy.


1. Trans-illumination
Biological microscopes feem ntau yog siv los soj ntsuam cov qauv pob tshab thiab yuav tsum tau illuminated nrog lub teeb kis. Muaj ob txoj kev teeb pom kev zoo
(1) Lub teeb ci tseem ceeb Tom qab lub teeb ci dhau los ntawm lub condenser, nws yog duab ntawm cov khoom dav hlau, raws li pom hauv daim duab 5. Yog tias qhov poob ntawm lub teeb lub zog tsis quav ntsej, qhov ci ntawm lub teeb pom kev zoo tib yam li lub teeb. qhov chaw nws tus kheej, yog li txoj kev no yog sib npaug rau qhov muab lub teeb ci rau ntawm qhov khoom dav hlau. Obviously, nyob rau hauv qhov tseem ceeb illumination, yog hais tias lub brightness ntawm qhov chaw ntawm lub teeb qhov chaw tsis zoo li, los yog pom tseeb hais tias cov qauv me me, xws li filaments, thiab lwm yam. tseem ceeb illumination. Txoj kev kho yog muab cov xim dawb thiab cov xim kub-absorbing nyob rau hauv pem hauv ntej ntawm lub teeb qhov chaw kom lub teeb pom kev zoo sib xws thiab tsis txhob muaj kev puas tsuaj rau cov khoom yuav tsum tau soj ntsuam vim lub sij hawm ntev irradiation ntawm lub teeb qhov chaw. Thaum illuminated nrog lub teeb xa mus, lub aperture lub kaum sab xis ntawm lub teeb pom kev ntawm lub hom phiaj lens yog txiav txim siab los ntawm lub kaum sab xis ntawm lub square beam ntawm daim iav condenser. Txhawm rau kom siv tag nrho cov lej aperture ntawm lub hom phiaj lens, lub condenser lens yuav tsum muaj tib yam lossis me ntsis loj dua tus lej aperture raws li lub hom phiaj lens.


(2) Kola teeb pom kev zoo Qhov tsis zoo ntawm qhov teeb pom kev tsis sib xws ntawm cov khoom nto hauv qhov teeb pom kev tseem ceeb tuaj yeem raug tshem tawm hauv Kola teeb pom kev zoo. Lub lens auxiliary condenser 2 yog ntxiv ntawm lub teeb qhov chaw 1 thiab lub condenser lens 5, raws li qhia hauv daim duab. 6. Nws tuaj yeem pom tau tias qhov kev pom (cov qauv) ntawm lub hom phiaj lub lens yog qhov sib txawv vim qhov teeb pom kev tsis ncaj qha, tab sis lub koom haum condenser 2 (tseem hu ua Kolar daim iav) uniformly illuminated los ntawm lub teeb qhov chaw yog imaged ntawm lub kev 6.


2. epi-illumination
Thaum soj ntsuam cov khoom opaque, xws li kev soj ntsuam cov hlau sib tsoo discs los ntawm lub tshuab ntsuas metallographic, nws feem ntau illuminated los ntawm sab lossis sab saud. Lub sijhawm no, tsis muaj iav npog ntawm qhov chaw ntawm qhov khoom yuav tsum tau soj ntsuam, thiab cov duab ntawm cov qauv yog tsim los ntawm lub teeb pom kev los yog tawg mus rau hauv lub hom phiaj lens.


3. Txoj kev teeb pom kev zoo rau kev soj ntsuam cov khoom siv qhov tsaus nti
Ultramicroscopic hais tuaj yeem pom nrog txoj kev tsaus ntuj. Lub npe hu ua ultramicroscopic particles hais txog cov khoom me me uas me dua qhov kev daws teeb meem ntawm lub tshuab tsom. Lub hauv paus ntsiab lus ntawm kev teeb pom kev tsaus ntuj yog: tsis txhob cia lub teeb pom kev tseem ceeb nkag mus rau lub hom phiaj lens, thiab tsuas yog lub teeb tawg los ntawm cov khoom tuaj yeem nkag mus rau lub hom phiaj lens rau kev yees duab. Yog li ntawd, cov duab ntawm cov khoom ci ci yog muab rau ntawm qhov tsaus ntuj. Txawm hais tias lub keeb kwm yav dhau ntawm qhov kev pom yog qhov tsaus ntuj, qhov sib piv (contrast) zoo heev, uas tuaj yeem txhim kho qhov kev daws teeb meem.


Tsaus teb illumination tuaj yeem muab faib ua ib-txoj kev thiab ob-txoj kev
(1) Ib-txoj kev tsaus ntuj illumination Daim duab 8 yog ib daim duab schematic ntawm ib-txoj kev tsaus ntuj illumination. Nws tuaj yeem pom los ntawm daim duab tias tom qab lub teeb tawm los ntawm lub teeb pom kev zoo 2 tau cuam tshuam los ntawm opaque specimen sheet 1, lub teeb tseem ceeb tsis nkag mus rau lub hom phiaj lens 3, thiab lub teeb nkag mus rau lub hom phiaj lens feem ntau yog tawg los ntawm cov khoom lossis tsis sib xws. paub meej. Obviously, qhov no ib-txoj kev tsaus ntuj illumination yog zoo rau kev soj ntsuam lub hav zoov thiab txav ntawm hais, tab sis nws tsis zoo rau reproducing cov ntsiab lus ntawm cov khoom, uas yog, muaj ib tug tshwm sim ntawm "distortion".


(2) Ob-txoj kev tsaus ntuj illumination Ob-txoj kev tsaus ntuj illumination tuaj yeem tshem tawm qhov tsis xws luag los ntawm ib txoj kev. Nyob rau hauv pem hauv ntej ntawm peb-lens condenser, tso ib tug annular diaphragm, raws li qhia nyob rau hauv daim duab 9, kom paub ob-txoj kev tsaus ntuj illumination. Cov kua yog immersed nyob nruab nrab ntawm qhov kawg ntawm lub condenser thiab lub hom phiaj iav, thaum qhov chaw ntawm lub hau npog iav thiab lub hom phiaj lens yog qhuav. Yog li ntawd, cov cuab yeej tshuaj ntsuam xyuas metallographic tau nruab nrog kev sib kis thiab epi-hom illumination ntawm lub tshuab tsom, thiab cov kab hluav taws xob annular dhau los ntawm lub condenser yog tag nrho cuam tshuam rau hauv lub khob iav thiab tsis tuaj yeem nkag mus rau lub hom phiaj lens, tsim ib lub voj voog raws li qhia hauv daim duab. . Tsuas yog lub teeb tawg los ntawm cov khoom ntawm cov qauv nkag mus rau lub hom phiaj lens, tsim ob txoj kev tsaus ntuj teeb pom kev zoo. Rau lwm yam cuab yeej xws li molten hlau analyzer, carbon silicon analyzer, thiab lwm yam, thov sab laj Tongpu Technology Department.

 

1 Digital Electronic Continuous Amplification Magnifier -

Xa kev nug