1. Ua ntej siv lub ntsuas pH portable thawj zaug lossis tsis siv lub sijhawm ntev, nyeem cov txheej txheem kev ua haujlwm no kom ntxaws. Cov pH electrode uas siv thawj zaug los yog tsis tau siv ntev yuav tsum tau tsau rau hauv 3mol / L potassium chloride tov rau 24 teev ua ntej siv. Yog tias lub ntsuas pH portable tsis txuas nrog lub electrode, nco ntsoov txuas lub pH (Q9) luv-circuit plug. Qhov kev ua haujlwm ib puag ncig kub ntawm lub ntsuas pH portable yog 5 ~ 35 degree, qhov ntsuas kub yog 0.0~6{{10}}}.0 degree, ntsuas ntau yog 0.00~14.


2. Equilibrate qhov kub ntawm cov tshuaj tsis haum rau hauv chav tsev kub.


3. Ntsuas qhov ntsuas kub ntawm cov tshuaj yuav tsum tau kuaj (yog tias tsim nyog), ntsuas pH tus nqi ntawm cov tshuaj uas yuav tsum tau kuaj, thiab xaiv ob qhov kev daws teeb meem tsis haum rau calibrate electrode.


4. Tshem tawm lub hau npog tiv thaiv electrode, muab cov electrode tso rau hauv qhov kev daws teeb meem, nias lub pob "ON / OFF" kom qhib nws, nias lub pob "Hom / Ntsuas" kom paub meej tias lub ntsuas ntsuas nyob rau hauv lub xeev ntsuas, tom qab ntawd kev nyeem ntawv ruaj khov, nias lub pob "Confirmation/Print" kom paub meej tias Calibration tshwm sim. Qhov sib txawv ntawm tus nqi calibration thiab tus qauv tus nqi ntawm ob qhov kev daws teeb meem tsis yog nyob rau hauv qhov kev tso cai ua ntej qhov ntsuas tuaj yeem txuas ntxiv. (Yog tsis muaj kev ntxuav, tsis txhob nqa cov electrode tawm ntawm ib qho kev daws teeb meem thiab muab tso ncaj qha rau hauv lwm qhov kev daws teeb meem lossis cov tshuaj yuav tsum tau sim)


5. Thaum qhov kub thiab txias electrode txuas nrog, qhov ntsuas tau txais kev them nyiaj kub tsis siv neeg, thiab tsis tas yuav teeb qhov ntsuas kub. Thaum lub ntsuas kub electrode tsis txuas, lub ntsuas pH portable tau txais kev them nyiaj kub ntawm phau ntawv. Lub sijhawm no, nias lub pob "Hom / Ntsuas", hauv "MTC" hom Teeb qhov ntsuas kub ntawm cov tshuaj yuav tsum tau kuaj.


6. Muab cov electrode tso rau hauv cov kev daws teeb meem, nias lub pob "Mode/Measure" kom paub meej tias lub ntsuas ntsuas nyob rau hauv lub xeev ntsuas, thiab thaum nyeem ntawv ruaj khov, nias "Confirm/Print" los ntsuas thiab luam cov ntaub ntawv. . Nias "Mode/Measurement" los hloov ntawm lub xeev hom thiab ntsuas lub xeev, lossis tshem tawm cov haujlwm tam sim no. Nias tus yuam sij "▲/PH/mv" los hloov qhov ntsuas ntsuas (PH lossis mv), xaiv hom lossis kho qhov ntsuas.


7. Tshem tawm cov electrode thiab ntxuav nws, thiab qhov ntsuas tau dhau lawm. Kaw rau pem hauv ntej kawg ntawm lub electrode nrog lub tes tsho tiv thaiv, thiab muab ib tug me me ntawm cov poov tshuaj chloride ntxiv tov rau hauv lub tes tsho tiv thaiv kom lub electrode noob moist; Nyob rau tib lub sijhawm, thov txav cov roj hmab sheath rau sab sauv ntawm cov electrode kom npog cov poov tshuaj chloride filling qhov kom tiv thaiv cov tshuaj chlorine Potassium chloride kua overflows.

 