Lwm Txoj Haujlwm ntawm Multimeters hauv Kev Kho Kev Ua Haujlwm

Mar 27, 2026

Lwm Txoj Haujlwm ntawm Multimeters hauv Kev Kho Kev Ua Haujlwm

 

(1) Txoj Kev Ntsuas Tam Sim No

Yuav tsum muaj ib lub multimeter rau kev kuaj tam sim no. Cov txheej txheem tshwj xeeb yog raws li hauv qab no: tua tag nrho cov khoom siv hluav taws xob hauv lub tsheb thiab tshem tawm cov yuam sij ignition. Siv cov khoom siv clamp tam sim no ntawm lub tsheb multimeter los ntsuas qhov tam sim no. Yog tias qhov kev nyeem ntawv nyob nruab nrab ntawm 10 mA thiab 30 mA, lub tsheb tsis muaj kab mob cab. Hloov pauv, yog tias qhov kev nyeem ntawv siab dhau lawm, lub cev hluav taws xob hluav taws xob ua txhaum yog tam sim no.

 

Nco ntsoov tias qee lub tsheb tseem tseem kos qhov tam sim no tsis pub dhau 15 feeb tom qab qhov hluav taws xob tua. Yog tias qhov ntsuas tam sim no tshaj 50 mA, rov ua dua tom qab tos 15 feeb. Yog tias qhov tam sim no tseem siab dua 50 mA tom qab lub sijhawm no, cov kab mob cab tau raug lees paub thiab yuav tsum kuaj xyuas ntxiv.

 

Thaum cov dej xau tau lees paub, khaws lub clamp tam sim no ntawm lub roj teeb tsis zoo. Tshem tawm fuses ib los ntawm ib qho thaum saib cov kev hloov pauv hauv kev nyeem tam sim no. Yog tias tshem tawm lub fuse ua tsis muaj kev hloov pauv tam sim no, qhov xau tsis tshwm sim hauv qhov Circuit Court. Yog tias qhov kev nyeem ntawv poob rov qab mus rau qhov qub ntawm 10-30 mA (qee lub tsheb tso cai qis dua 50 mA nyob ntawm tus qauv), qhov xau ploj mus, qhia tau hais tias lub Circuit Court tswj los ntawm lub fuse no muaj qhov xau, grounding short-circuit lossis circuit faults.

 

(2) Kev kuaj mob ceev ntawm cov khoom siv hluav taws xob

Kev ntsuas tam sim no tseem tuaj yeem kuaj xyuas qhov yuam kev hauv ntau lub tsheb hluav taws xob, xws li lub taub hau, lub tshuab suab, roj twj tso kua mis relays, lub hwj chim qhov rais motors, alternators thiab lwm yam khoom siv hluav taws xob.

Siv lub twj tso kua roj hluav taws xob ua piv txwv:

 

Yog hais tias qhov kev khiav hauj lwm tam sim no nyeem 4.5 A, cov roj twj tso kua mis ua haujlwm ib txwm.

Kev txiav tawm ntawm cov roj sib txuas feem ntau yog tshwm sim los ntawm kev sib txuas tsis zoo.

 

Yog tias qhov tam sim no qis dua 4.5 A, qhov txawv txav tsis zoo, kev sib cuag tsis zoo, lossis cov roj av qias neeg tuaj yeem thaiv lub tshuab nqus dej; lub twj tso kua mis khiav tsis muaj load thiab qhia tau tias txo tam sim no.

 

Yog tias qhov tam sim no siab dua 4.5 A, cov roj lim yuav tuaj yeem txhaws lossis qee qhov thaiv, ua kom lub twj tso kua mis load.

Misdiagnosis yog tshwm sim nyob rau hauv cov xwm txheej zoo li no thiab yuav tsum tau ua tib zoo zam thaum kuaj.

 

4 Multimeter 9999 counts