MPO Method rau Txheej Thickness Gauge Calibration

Jun 28, 2023

MPO Method rau Txheej Thickness Gauge Calibration

 

Xws li: 1. Copper, chromium, zinc thiab lwm yam electroplating txheej los yog xim, xim, enamel thiab lwm yam txheej thicknesses ntawm cov ntaub ntawv hlau.
2. Thickness ntawm txhuas, tooj liab, kub thiab lwm yam ntaub ntawv ci thiab sawb, ntawv thiab yas zaj duab xis.
3. Txheej thickness ntawm cov ntaub ntawv uas tsis yog-ferrous xws li tooj liab, txhuas, magnesium, zinc, thiab lwm yam.
4. Thickness ntawm anodized zaj duab xis ntawm txhuas thiab magnesium cov ntaub ntawv.
5. Thickness ntawm thermal spray txheej ntawm ntau yam hlau thiab cov ntaub ntawv tsis-ferrous hlau.


Txheej thickness gauge MPO calibration txoj kev:
1 Hloov lub twj paj nruag rau / tawm
Nco tseg: Lub ntsuas ntsuas tsis muaj qhov hloov pauv tshwj xeeb.
 

Qhib lub ntsuas
- Tsis siv neeg tig thaum lub ntsuas tau muab tso rau ntawm qhov chaw ua haujlwm. Yog tias qhov ntsuas tau muab tso rau ntawm cov khoom siv tsis yog ferromagnetic los yog cov khoom siv tsis zoo, cov zaub yuav pom "Er6" ua raws li plaub kab kab rov tav yam tsis muaj kev nyeem ntawv.
- Lwm txoj hauv kev los qhib lub zog yog nias tus yuam sij [OK].

Thov nco ntsoov!
Tsis txhob hloov lub ntsuas los ntawm nias lub sensor nrog koj tus ntiv tes! Qhov no tuaj yeem ua rau qhov ntsuas tsis raug.


Tua lub ntsuas / pib kaw
Lub cuab yeej yuav cia li kaw tom qab ib feeb ntawm kev tsis ua haujlwm. (OFF=ntsuas ntsuas tsis pom dab tsi).

Ntsuas Txheej Thickness
1. Tom qab lub ntsuas hluav taws xob qhib, tso lub ntsuas hluav taws xob rau ntawm qhov chaw ua haujlwm yuav tsum ntsuas thiab tos lub ntsuas ntsuas ntsuas lub suab. Ua li no, lub ntsuas hluav taws xob tuaj yeem qhib tau.
2. Nqa lub ntsuas tawm ntawm lub workpiece.
Kev nyeem ntawv yog tshwm sim tom qab ntsuas lub suab. Faj seeb: Yog tias lub cuab yeej raug tshem tawm ntxov dhau (ua ntej muaj suab), cov lus yuam kev "Er6" yuav tshwm sim. Rov ua kauj ruam 1.
3. Thaum lub ntsuas ntsuas twb nyob rau, qhov kev nyeem ntawv yuav tshwm sim tam sim ntawd. Nws yuav tshwm sim thaum lub ntsuas tau muab tso rau ntawm qhov ntsuas workpiece thiab tom qab nws nqa.
Ntsuas nrog MP0


Tso cov ntaub ntawv ntsuas uas khaws cia hauv qhov ntsuas
Cov cuab yeej tuaj yeem khaws txog 999 cov ntaub ntawv ntsuas.
1. Siv [5] tus yuam sij lossis [6] tus yuam sij los rub los ntawm cov ntaub ntawv ntsuas.
2. Tom qab xa cov ntaub ntawv ntsuas thawj zaug lossis zaum kawg, lub vijtsam yuav tso tawm "- - - -" li ntawm 1 thib ob.
Koj tuaj yeem ntsuas ntsuas txuas ntxiv txhua lub sijhawm.


Tshem tawm tag nrho cov ntaub ntawv ntsuas
1. Nias tus yuam sij [5] lossis [6].
2. Nias tus yuam sij [CAL].
"del" rho tawm yuav tshwm rau 2 vib nas this.
3. Nias tus yuam sij [OK] thaum "del" tshwm sim.
Tag nrho cov ntaub ntawv ntsuas hauv qhov ntsuas yuav raug muab tshem tawm.
Nias tus yuam sij [OK] thaum "del" tsis tshwm sim yuav tsis muaj txiaj ntsig.


Li qub
Normalization yog siv los hloov kho cov cuab yeej ntsuas. Normalization yuav tsum tau ib tug unplated substrate, thiab cov duab thiab cov khoom ntawm lub substrate yuav tsum tau raws li lub workpiece yog ntsuas.
Nco tseg: Normalization yuav rho tawm tag nrho cov ntaub ntawv nco.
Normalize lub ntsuas (yuav tsum tau ua ua ntej: lub ntsuas yog qhib)
1. Nias tus yuam sij [CAL]. "Base" (ie "unplated substrate") yog tso tawm kom pom.
2. Ntsuas li tsib zaug ntawm lub substrate
Tom qab txhua qhov ntsuas, qhov kev nyeem ntawv tam sim no tau tshwm sim.
3. Nias tus yuam sij [OK] ob zaug.
Qhov screen qhia "Er17", tsis quav ntsej nws.
Ua kom tiav cov txheej txheem normalization.
(Coating thickness gauge MPO calibration method) cov kauj ruam;


calibration
Calibration yuav tsum muaj cov khoom nram qab no: substrate (cov duab thiab cov khoom ntawm lub substrate yuav tsum tau raws li ib feem yuav tsum tau kuaj) thiab ib tug standard piece (tus qauv piece ntawm txog 75 µm random muab los ntawm lub ntsuas). Nco tseg: Calibration yuav tshem tawm tag nrho cov kev nyeem hauv lub cim xeeb.

Calibrate qhov ntsuas (yuav tsum tau ua ua ntej: lub ntsuas yuav tsum tau hloov mus rau)
1. Nias tus yuam sij [CAL].
Tso saib "Base" (ie "unplated substrate")
2. Ntsuas li tsib zaug ntawm lub substrate.
Tom qab txhua qhov ntsuas, qhov kev nyeem ntawv tam sim no tau tshwm sim.
3. Nias tus yuam sij [OK].
Qhia 0.00 thiab STD1 (ie Calibration Standard #1).
4. Muab tus qauv calibration rau ntawm lub substrate thiab ntsuas li 5 zaug.
Tom qab txhua qhov ntsuas, qhov kev nyeem ntawv tam sim no tshwm rau ntawm qhov screen.
5. Siv tus yuam sij [5] lossis [6] los kho tus nqi kawg hauv qib 4 mus rau tus nqi nominal ntawm daim ntawv txheej txheem, xws li "75 µm". Tus nqi nominal ntawm daim ntawv txheem yog qhia rau ntawm daim ntawv txheem.
6. Nias tus yuam sij [OK].
Cov txheej txheem calibration tiav. Cov cuab yeej rov qab mus rau lub xeev ntsuas.


Rho tawm cov ntaub ntawv calibration / restore qub nkhaus
Qee zaum, yog tias qhov ntsuas ntsuas tseem tsis raug tom qab calibration, calibration tsis tuaj yeem raug tshem tawm. Qhov no tuaj yeem tshwm sim yog tias cov txheej txheem calibration yav dhau los tsis tau ua kom raug.
Nyob rau hauv rooj plaub no, tus yam ntxwv nkhaus tuaj yeem rov qab mus rau qhov chaw tsim khoom qub.


Rho tawm cov calibration parameters (yuav tsum tau ua ntej: lub ntsuas yuav tsum tau qhib)
1. Nias tus yuam sij [CAL]. "Base" yuav tshwm rau ntawm qhov screen.
2. Ntsuas li 5 zaug ntawm lub substrate.
3. Nias tus yuam sij [OK]. "STD1" (Calibration Standard #1) yog tshwm sim.
4. Ntsuas 1 zaug ntawm lub substrate.
Lub vijtsam yuav qhia kev nyeem ib puag ncig 0.
5. Siv [5] lossis [6] tus yuam sij los kho STD1 rau 0.00.
Lub vijtsam yuav tso tawm "0.00 STD1".
6. Nias tus yuam sij [OK]. Rov qab mus rau qhov qub yam ntxwv nkhaus.
Kev txum tim tiav. Tam sim no lub ntsuas tau npaj los ntsuas.

 