+86-18822802390

Yuav ua li cas txheeb xyuas seb lub Sensor puas ua haujlwm siv Multimeter

May 31, 2026

Yuav ua li cas txheeb xyuas seb lub Sensor puas ua haujlwm siv Multimeter

 

1. Lub chaw tsim khoom sensor muab lub sensor tso zis rhiab heev thiab lub hwj chim mov voltage ntawm lub Hoobkas, thiab peb ntes lub sensor tso zis teeb liab raws li ob qhov tsis.

 

Lub ntsuas ntsuas ntsuas qhov hnyav ntawm lub zog ntsuas qhov ntsuas qhov ntsuas qhov ntsuas analog hauv millivolts. Piv txwv li, lub sensor tso zis rhiab heev yog 2.0mV / V, thiab lub hwj chim mov voltage yog DC10V. Ob qhov kev ntsuas no tuaj yeem ua rau peb muaj kev sib raug zoo ntawm lub sensor excitation ua hauj lwm voltage xav tau DC10V thiab lub sensor tso zis teeb liab coj mus rau ib tug 2.0mV excitation voltage tso zis rau txhua txhua 1V.
Piv txwv li, yog tias tag nrho ntau yam ntawm lub sensor yog 50KG, ces muab lub sensor rau DC10V voltage thiab tso zis 20mV ntawm tag nrho cov ntau yam. Raws li qhov kev sib raug zoo no, peb siv lub multimeter mV los ntsuas lub sensor tso zis teeb liab.

 

Qhov tsis muaj-load tso tawm ntawm lub sensor yog 0mV, uas yog qhov qub. Yog tias nws ntau dua tus nqi no, tab sis ze rau tus nqi no, qhov kev hloov pauv ntawm tus lej qhia tias lub sensor muaj xoom drift. Yog tias tus nqi loj, nws qhia tau tias lub sensor
Kev puas tsuaj los yog choj sab hauv yog ib lub voj voog nrog asymmetric choj caj npab tsis kam.

 

2. Txiav txim siab seb lub ntsuas ntsuas qhov ntsuas qhov ntsuas puas puas raws li qhov ntsuas qhov ntsuas tau muab los ntawm lub Hoobkas, kev tawm tswv yim tsis kam, thiab tso tawm tsis kam.
Qhov kev tawm tswv yim thiab tso tawm qhov tseem ceeb ntawm cov sensors txawv ntawm cov chaw tsim khoom rau cov chaw tsim khoom. Yog li qhov no yuav tsum tau kuaj xyuas raws li tus neeg tsim khoom daim ntawv lo. Siv ib lub multimeter los ntsuas qhov tsis kam ntawm cov khoom siv hluav taws xob thiab lub zog hauv av, nrog rau qhov tsis kam ntawm cov teeb liab kab thiab teeb liab hauv av. Yog tias tus nqi tiv thaiv ntau dua li lub Hoobkas tiv thaiv tus nqi, nws qhia tau hais tias lub sensor tau dhau lawm thiab qhov ntsuas ntsuas tau deformed. Yog hais tias tus nqi kuj yog infinite, lub sensor strain gauge yog heev puas thiab kho tsis tau.

 

3. Vim tias cov hlau tawg tsis tu ncua thaum siv lub sensor, thaum lub txheej txheej ntawm cov hlau tiv thaiv tsis zoo, peb pom kev kuaj xyuas qhov tseeb ntawm cov xaim sensor. Peb siv lub ohm ntau yam ntawm ib tug multimeter los xyuas qhov txuas ntxiv ntawm lub sensor hlau. Yog tias qhov kev tiv thaiv tsis kawg, nws yog qhov tseeb tias yuav tawg, thiab yog tias qhov hloov pauv hloov, kev sib cuag tsis zoo.

 

pocket multimeter

Xa kev nug