+86-18822802390

Kev Tiv Thaiv Kev Ua Haujlwm Txhua Hnub rau Gas Detectors

Jan 17, 2026

Kev Tiv Thaiv Kev Ua Haujlwm Txhua Hnub rau Gas Detectors

 

1, Kev teeb tsa lub tshuab ntsuas roj: Ua ntej, kev xaim hluav taws xob: Cov xov hlau muaj kev tiv thaiv siab yuav tsum tau siv los tiv thaiv kev cuam tshuam nrog cov teeb liab hluav taws xob. Cov xov hlau yuav tsum tau teem caij kom zoo thiab lub hau npog sab saum toj yuav tsum qhib. Gas detectors feem ntau siv peb lub xaim xaim. Lub davhlau ya nyob twg zoo ntawm cov khoom siv hluav taws xob (cim li "VCC" davhlau ya nyob twg), cov kab teeb liab (cim li "SIG" davhlau ya nyob twg), thiab lub davhlau ya nyob twg tsis zoo ntawm lub zog hluav taws xob (cim li "GND" lub davhlau ya nyob twg) txuas nrog cov txheej txheem terminals sau tias "4-20mAIN" hauv channel module, sib thooj rau "2VND", mA. Lub chassis hauv av (shielding network ntawm cable) yog zoo grounded, thiab tom qab txuas cov xov hlau, lub chassis yog fastened. Pib: Kev xaim ua tiav, fais fab mov rau lub tshuab ntes. Tom qab pib ua haujlwm, kev nyeem ntawv yuav mus los ntawm ntau yam mus rau qhov ruaj khov, uas yuav siv sijhawm li 15 feeb. Qhov thib ob yog txhawm rau txhim kho lub ntsuas roj hauv ib cheeb tsam uas yuav muaj roj to. Kev teeb tsa ntawm lub tshuab ntsuas roj yuav tsum ruaj khov, thiab txoj haujlwm teeb tsa yog txiav txim siab los ntawm qhov tshwj xeeb lub ntiajteb txawj nqus ntawm cov ntsuas roj txheeb ze rau huab cua. Raws li qhov tshwj xeeb lub ntiajteb txawj nqus ntawm cov roj ntsuas yog me dua li ntawm huab cua, lub detector yuav tsum tau ntsia ntawm qhov deb ntawm 30-60cm ntawm lub qab nthab. Txhim kho lub ntes ntawm phab ntsa nrog Φ 8 expansion ntsia hlau. Txhawm rau siv lub ntsuas ntsuas kom zoo thiab tiv thaiv nws qhov tsis ua haujlwm, thov tsis txhob nruab nws hauv cov chaw hauv qab no:

Qhov chaw ncaj qha cuam tshuam los ntawm chav thiab roj fumes; Cov chaw uas muaj huab cua siab, xws li cua tshuab, cua kiv cua, thiab qhov rooj; Cov chaw uas muaj dej vapor siab thiab cov tee dej (qhov txheeb ze av noo: ntau dua 90%); Qhov chaw nrog kub hauv qab -40℃lossis siab dua 70 degree.

 

2, Yam tseem ceeb uas yuav tsum tau xav txog ua ntej siv lub tshuab ntsuas roj: Ua ntej nkag mus rau qhov chaw kaw thiab / lossis cov thawv ntim khoom, nws yuav tsum tau kuaj xyuas seb thaj chaw ua haujlwm puas muaj kev nyab xeeb thiab seb yuav tsum tau ua li cas, xws li kev teeb tsa cov khoom siv cua. Puas muaj tej yam tshuaj lom lossis tawg hauv cheeb tsam? Yog tias muaj, lawv yog dab tsi? Qhov qib oxygen nyob ntawd yog dab tsi? Yog tias kev ntsuas qib kev ruaj ntseg tuaj yeem ua tau raug, ces ob nqe lus nug no tuaj yeem teb tau. Yog tias lub thawv tau ntim tag nrho, nws tseem ua lub luag haujlwm tseem ceeb hauv kev ntsuas kev pheej hmoo, tsis hais seb puas muaj cov pa phem tso pa tawm lossis cov khoom phom sij nkag mus.

 

3, Yuav ua li cas tuav lub ntsuas roj: Kev tshuaj xyuas tag nrho lub tshuab: Lub tshuab kuaj xyuas yuav tsum tau kuaj xyuas tsis tu ncua, thiab nws cov teeb liab tam sim no yog DC4mA hauv huab cua huv; Kev saib xyuas sensor: Feem ntau, rov kuaj xyuas thiab ntsuas qhov ntsuas yuav tsum tau ua tom qab rau lub hlis mus rau ib xyoos ntawm kev teeb tsa thiab siv, thiab daim ntawv tshaj tawm kev xeem yuav tsum tau muab los ntawm pawg xeem; Thaum lub sensor ntawm lub ntsuas roj poob rhiab heev, nws yuav tsum tau hloov. Tsis tu ncua calibration yuav txiav txim seb lub sensor puas ua tsis tau. Thaum tus nqi calibration tsis ncav cuag tus qauv roj tus nqi, lub sensor yuav tsum tau hloov.

 

-5 Gas Leak Detector

 

Xa kev nug