Kev xaiv kom raug ntawm tus pas ntsuas kub infrared

Apr 21, 2023

Tso lus

Kev xaiv kom raug ntawm tus pas ntsuas kub infrared

 

Kev xaiv ntawm tus pas ntsuas kub infrared tuaj yeem muab faib ua peb yam:


(1) Cov ntsuas kev ua tau zoo, xws li qhov kub thiab txias, qhov loj me, ua haujlwm wavelength, ntsuas qhov tseeb, qhov rais, tso saib thiab tso zis, lub sijhawm teb, cov khoom siv tiv thaiv, thiab lwm yam;


(2) Ib puag ncig thiab kev ua haujlwm, xws li ambient kub, qhov rais, tso saib thiab tso zis, cov khoom siv tiv thaiv, thiab lwm yam;


(3) Lwm yam kev xaiv, xws li kev yooj yim ntawm kev siv, kev saib xyuas thiab kev ntsuas kev ua haujlwm, thiab tus nqi, kuj muaj qee yam cuam tshuam rau kev xaiv cov ntsuas kub.
Nrog rau kev txhim kho txuas ntxiv ntawm kev siv tshuab thiab thev naus laus zis, kev tsim qauv zoo tshaj plaws thiab kev nce qib tshiab ntawm cov ntsuas kub infrared muab cov neeg siv nrog ntau lub zog thiab ntau lub hom phiaj, nthuav kev xaiv. Lwm yam kev xaiv xws li kev yooj yim ntawm kev siv, kho thiab calibration peev xwm, thiab tus nqi. Thaum xaiv tus qauv ntsuas kub, koj yuav tsum xub txiav txim siab txog qhov yuav tsum tau ntsuas, xws li qhov ntsuas kub ntawm lub hom phiaj yuav tsum ntsuas, qhov loj ntawm lub hom phiaj yuav tsum ntsuas, qhov ntsuas qhov deb, cov khoom ntawm lub hom phiaj yuav tsum ntsuas, ib puag ncig ntawm lub hom phiaj, teb ceev, ntsuas qhov tseeb, portable los yog hauv internet, thiab lwm yam .; Nyob rau hauv kev sib piv ntawm ntau yam uas twb muaj lawm qauv ntawm tus pas ntsuas kub, xaiv lub ntsuas qauv uas yuav ua tau raws li cov saum toj no cov kev cai; xaiv qhov zoo tshaj plaws match nyob rau hauv cov nqe lus ntawm kev ua tau zoo, kev ua haujlwm thiab tus nqi ntawm ntau cov qauv uas tuaj yeem ua tau raws li qhov xav tau saum toj no.


Txiav txim siab qhov kub thiab txias
Txiav txim siab qhov ntsuas kub ntawm qhov ntsuas kub: Qhov ntsuas qhov ntsuas kub yog qhov tseem ceeb tshaj qhov ntsuas qhov ntsuas kub ntawm tus pas ntsuas kub. Piv txwv li, Raytek (Raytek) cov khoom lag luam npog ntau yam ntawm -50 degree - ntxiv rau 3000 degree, tab sis qhov no tsis tuaj yeem ua los ntawm ib hom ntsuas kub infrared. Txhua hom ntsuas kub muaj nws tus kheej qhov kub thiab txias. Yog li ntawd, tus neeg siv qhov ntsuas kub ntawm qhov ntsuas kub yuav tsum tau txiav txim siab kom raug thiab ua tiav, tsis yog nqaim dhau lossis dav dhau. Raws li txoj cai lij choj ntawm blackbody hluav taws xob, qhov kev hloov ntawm hluav taws xob hluav taws xob los ntawm qhov kub thiab txias nyob rau hauv lub luv-yoj band ntawm lub spectrum yuav dhau qhov kev hloov ntawm hluav taws xob hluav taws xob los ntawm emissivity yuam kev. Yog li ntawd, nws yog qhov zoo dua los siv luv-yoj ntau npaum li qhov ua tau thaum ntsuas kub. Feem ntau hais lus, qhov nqaim ntawm qhov ntsuas qhov ntsuas kub ntau dua, qhov siab dua qhov kev daws teeb meem ntawm qhov tso zis ntawm qhov ntsuas kub yog, thiab qhov tseeb thiab kev ntseeg tau yooj yim los daws. Yog tias qhov ntsuas qhov ntsuas kub ntau dhau, qhov ntsuas kub ntsuas qhov tseeb yuav raug txo. Piv txwv li, yog tias qhov ntsuas kub ntawm lub hom phiaj yog 1000 degrees Celsius, thawj zaug txiav txim seb nws puas yog online lossis portable, thiab yog tias nws yog portable. Muaj ntau cov qauv uas ua tau raws li qhov ntsuas kub no, xws li 3iLR3, 3i2M, 3i1M. Yog tias qhov ntsuas qhov tseeb yog qhov tseem ceeb, nws yog qhov zoo dua los xaiv hom 2M lossis 1M, vim tias yog siv hom 3iLR, qhov ntsuas qhov ntsuas kub yog qhov dav heev, thiab qhov ntsuas kub ntawm qhov ntsuas kub yuav tsis zoo; Rau cov hom phiaj kub qis, peb yuav tsum xaiv 3iLR3.


Txiav txim qhov loj me
Cov ntsuas kub infrared tuaj yeem muab faib ua cov ntsuas kub ib leeg thiab ob-xim ntsuas kub (radiation colorimetric thermometers) raws li txoj cai. Rau ib tus pas ntsuas kub monochromatic, thaum ntsuas qhov ntsuas kub, thaj tsam ntawm lub hom phiaj yuav tsum tau ntsuas yuav tsum ua kom pom qhov pom ntawm tus pas ntsuas kub. Nws raug pom zoo tias qhov ntsuas lub hom phiaj loj tshaj 50 feem pua ​​​​ntawm qhov kev pom. Yog tias lub hom phiaj loj me dua qhov kev pom, lub zog hluav taws xob tom qab yuav nkag mus rau qhov pom thiab acoustic cov cim ntawm tus pas ntsuas kub thiab cuam tshuam rau qhov ntsuas kub ntsuas, ua rau yuam kev. Hloov pauv, yog tias lub hom phiaj loj dua li qhov pyrometer qhov kev pom, lub pyrometer yuav tsis cuam tshuam los ntawm keeb kwm yav dhau los ntawm thaj chaw ntsuas. Rau colorimetric thermometers, qhov kub thiab txias yog txiav txim siab los ntawm qhov sib piv ntawm lub zog hluav taws xob nyob rau hauv ob qhov kev ywj pheej wavelength bands. Yog li ntawd, thaum lub hom phiaj yuav tsum tau ntsuas me me, tsis ua kom tiav qhov kev pom, thiab muaj cov pa taws, plua plav, thiab kev cuam tshuam ntawm txoj kev ntsuas, uas ua rau lub zog hluav taws xob txo qis, nws yuav tsis muaj qhov cuam tshuam loj rau kev ntsuas ntsuas. . Rau me me thiab txav los yog vibrating lub hom phiaj, tus pas ntsuas kub colorimetric yog qhov kev xaiv zoo tshaj plaws. Qhov no yog vim qhov me me ntawm lub teeb rays thiab lawv qhov yooj yim rau kev thauj lub teeb hluav taws xob hluav taws xob hla nkhaus, thaiv thiab folded raws.


Rau Raytek (Lei Tai) ob-xim ntsuas kub, nws qhov kub thiab txias yog txiav txim siab los ntawm qhov sib piv ntawm lub zog hluav taws xob nyob rau hauv ob qhov kev ywj pheej wavelength bands. Yog li ntawd, thaum lub hom phiaj yuav tsum tau ntsuas me me, tsis sau rau ntawm qhov chaw, thiab muaj cov pa taws, plua plav, lossis kev cuam tshuam ntawm txoj kev ntsuas uas ua rau lub zog hluav taws xob txo qis, nws yuav tsis cuam tshuam rau kev ntsuas qhov ntsuas. Txawm hais tias nyob rau hauv cov ntaub ntawv ntawm 95 feem pua ​​​​lub zog attenuation, qhov yuav tsum tau ntsuas kub ntsuas qhov tseeb tseem tuaj yeem lav. Rau cov hom phiaj me me thiab txav los yog vibrating; Qee zaum txav mus rau hauv qhov chaw saib, lossis qee zaum txav tawm ntawm qhov chaw saib, nyob rau hauv cov xwm txheej no, kev siv lub ntsuas kub ntawm ob xim yog qhov kev xaiv zoo tshaj plaws. Yog tias nws tsis tuaj yeem tsom ncaj qha ntawm lub pyrometer thiab lub hom phiaj, thiab kev ntsuas channel yog khoov, nqaim, thaiv, thiab lwm yam, ob-xim fiber optic pyrometer yog qhov kev xaiv zoo tshaj. Qhov no yog vim lawv txoj kab uas hla me me, hloov tau yooj yim, thiab muaj peev xwm xa cov hluav taws xob hluav taws xob hluav taws xob hla kev nkhaus, thaiv, thiab folded raws, yog li ua rau kev ntsuas ntawm cov hom phiaj uas nyuaj rau kev nkag mus, hauv cov xwm txheej hnyav, lossis nyob ze electromagnetic teb.


Kev txiav txim qhov kev ncua deb (kev daws teeb meem kho qhov muag)
Qhov kev ncua deb coefficient yog txiav txim siab los ntawm qhov piv ntawm D: S, uas yog, qhov sib piv ntawm qhov deb D ntawm qhov kev sojntsuam ntawm tus pas ntsuas kub rau lub hom phiaj thiab txoj kab uas hla ntawm lub hom phiaj yuav ntsuas. Yog hais tias tus pas ntsuas kub yuav tsum tau muab ntsia kom deb ntawm lub hom phiaj vim yog ib puag ncig ib puag ncig, thiab lub hom phiaj me me yuav tsum tau ntsuas, tus pas ntsuas kub uas muaj qhov siab kho qhov muag yuav tsum tau xaiv. Qhov siab dua qhov kev daws teeb meem kho qhov muag, piv txwv li nce qhov D: S piv, tus nqi siab dua ntawm cov pyrometer. Raytek Infrared Thermometers D: S muaj li ntawm 2: 1 (tsawg nyob deb qhov tseem ceeb) mus rau ntau tshaj 300: 1 (qhov tseem ceeb nyob deb). Yog hais tias tus pas ntsuas kub nyob deb ntawm lub hom phiaj thiab lub hom phiaj yog me me, tus pas ntsuas kub uas muaj qhov sib txawv siab yuav tsum tau xaiv. Rau ib tug pyrometer nrog ib tug taag focal ntev, lub focal point ntawm lub optical system yog qhov tsawg tshaj plaws txoj hauj lwm ntawm qhov chaw, thiab qhov chaw nyob ze thiab deb ntawm lub focal point yuav nce. Muaj ob yam nyob deb. Yog li ntawd, txhawm rau ntsuas qhov ntsuas kub ntawm qhov deb ntawm qhov ze thiab deb ntawm qhov ua kom pom tseeb, qhov loj ntawm lub hom phiaj ntsuas yuav tsum loj dua qhov chaw loj ntawm qhov tsom. Lub ntsuas kub zoom muaj qhov ua kom pom tseeb yam tsawg kawg nkaus, uas tuaj yeem hloov kho raws li qhov kev ncua deb ntawm lub hom phiaj. Yog tias D: S nce, lub zog tau txais yuav txo qis. Yog tias qhov tau txais aperture tsis tau nce, qhov kev ncua deb coefficient D:S yuav nyuaj rau nce, uas yuav ua rau tus nqi ntawm qhov ntsuas.


4.4 Kev txiav txim siab wavelength ntau yam
Lub emissivity thiab nto thaj chaw ntawm lub hom phiaj cov ntaub ntawv txiav txim lub spectral teb wavelength ntawm lub pyrometer. Rau siab reflectivity alloy cov ntaub ntawv, muaj tsawg los yog sib txawv emissivity. Nyob rau hauv qhov kub thiab txias, qhov zoo tshaj plaws wavelength rau ntsuas cov ntaub ntawv hlau yog ze-infrared, thiab 0 8-1 0 μm xaiv tau. Lwm qhov chaw kub tuaj yeem xaiv 1.6μm, 2.2μm thiab 3.9μm. Txij li qee cov ntaub ntawv yog pob tshab ntawm qee qhov wavelength, lub zog infrared yuav nkag mus rau cov ntaub ntawv no, thiab yuav tsum xaiv lub wavelength tshwj xeeb rau cov khoom no. Piv txwv li, 1. 5.0μm yog siv los ntsuas qhov kub ntawm lub khob; Piv txwv li, 3.43μm yog siv los ntsuas polyethylene yas zaj duab xis, 4.3μm los yog 7.9μm yog siv rau polyester, thiab 8-14μm yog siv rau thickness tshaj 0.4mm. Piv txwv li, qhov nqaim band 4.64μm yog siv los ntsuas CO hauv cov nplaim taws, thiab 4.47μm yog siv los ntsuas NO2 hauv cov nplaim taws.


4.5 Txiav txim siab lub sij hawm teb
Lub sij hawm teb qhia cov tshuaj tiv thaiv ceev ntawm lub ntsuas kub infrared mus rau qhov ntsuas kub hloov, uas txhais tau hais tias lub sijhawm yuav tsum ncav cuag 95 feem pua ​​​​ntawm lub zog ntawm kev nyeem ntawv zaum kawg, uas cuam tshuam nrog lub sij hawm tas li ntawm photodetector, teeb liab ua Circuit Court. thiab tso saib system. Lub sij hawm teb ntawm Raytek tus ntsuas kub infrared tshiab tuaj yeem ncav cuag 1ms. Qhov no yog sai dua li kev tiv thaiv kev ntsuas kub. Yog hais tias qhov txav ceev ntawm lub hom phiaj yog ceev heev los yog thaum ntsuas lub hom phiaj cua kub ceev, yuav tsum xaiv lub ntsuas kub ceev infrared, txwv tsis pub cov teeb liab txaus teb yuav tsis ua tiav, thiab qhov ntsuas qhov tseeb yuav raug txo. Txawm li cas los xij, tsis yog txhua daim ntawv thov yuav tsum muaj lub ntsuas kub ceev infrared. Rau cov txheej txheem zoo li qub lossis lub hom phiaj thermal qhov twg thermal inertia tshwm sim, lub sijhawm teb ntawm pyrometer tuaj yeem so. Yog li ntawd, qhov kev xaiv ntawm lub sij hawm teb ntawm tus pas ntsuas kub infrared yuav tsum tau yoog raws li qhov xwm txheej ntawm lub hom phiaj ntsuas. Kev txiav txim siab lub sij hawm teb feem ntau yog nyob ntawm qhov txav ceev ntawm lub hom phiaj thiab qhov kub hloov ceev ntawm lub hom phiaj. Rau cov hom phiaj zoo li qub lossis lub hom phiaj tsis nyob hauv thermal inertia, lossis qhov ceev ntawm cov cuab yeej tswj tau raug txwv, lub sij hawm teb ntawm tus pas ntsuas kub tuaj yeem so kom txaus.


4.6 Teeb liab ua haujlwm
Raws li qhov sib txawv ntawm cov txheej txheem tsis sib xws (xws li cov khoom tsim tawm) thiab cov txheej txheem txuas ntxiv, cov ntsuas kub infrared yuav tsum muaj ntau lub cim ua haujlwm (xws li ncov tuav, hav tuav, qhov nruab nrab tus nqi) xaiv los ntawm, xws li thaum ntsuas qhov kub ntawm lub raj mis ntawm txoj siv conveyor, nws yog siv lub ncov tuav, qhov kub thiab txias tso zis teeb liab raug xa mus rau tus maub los. Txwv tsis pub tus pas ntsuas kub nyeem qhov ntsuas kub qis ntawm cov fwj. Yog tias siv lub ncov tuav, teem lub sij hawm tus pas ntsuas kub kom ntev me ntsis ntev dua lub sij hawm ncua ntawm lub raj mis kom tsawg kawg ib lub raj mis nyob rau hauv kev ntsuas.

 

4 infrared thermometer 13 laser points

 

 

Xa kev nug