Tham txog txoj kev siv thiab ceev faj ntawm multimeter

Nov 15, 2022

Tso lus

Tham txog txoj kev siv thiab ceev faj ntawm multimeter


Multimeters tseem hu ua multimeters, multimeters, thiab multimeters. Lawv xa mus rau cov cuab yeej siv los ntsuas AC thiab DC voltages, tsis kam, DC tam sim no, thiab qib suab. Advanced multimeters kuj tseem siv tau los ntsuas AC tam sim no, capacitance, inductance thiab qee qhov tsis sib xws ntawm semiconductors (xws li ). Txhua yam, nws yog ib qho yuav tsum muaj cov cuab yeej siv hluav taws xob thiab xov tooj cua ntau lawm. Tom qab sau thiab txheeb xyuas cov ntaub ntawv, tus editor yuav qhia txog kev siv thiab kev ceev faj ntawm multimeter (digital multimeter siv) rau koj kom meej.


Feem ntau, peb yuav tsum nkag siab txog cov hauv qab no ua ntej siv multimeter (AC millivoltmeter):


(1) Paub txog lub ntsiab lus ntawm cov cim ntawm lub dial thiab lub luag haujlwm tseem ceeb ntawm txhua lub pob qhov rooj thiab qhov chaw xaiv.


(2) Ua raws li kev hloov kho tshuab xoom. Ntawd yog, thaum tsis muaj hluav taws xob ntsuas, ua tus pointer ntawm multimeter taw tes rau txoj hauj lwm ntawm xoom voltage lossis xoom tam sim no.


(3) Raws li hom thiab qhov loj ntawm cov khoom ntsuas, xaiv txoj haujlwm thiab ntau yam ntawm kev hloov pauv, thiab nrhiav cov kab sib txuas.


Rau qhov ntsuas qhov ntsuas hluav taws xob, ua kom lub taub hau ntawm qhov kev xaiv ntau yam hloov nrog tsib-ceev ntau yam cim nrog V. Yog tias ntsuas qhov ntsuas hluav taws xob AC, nws yuav tsum taw tes rau V. Los ntawm kev sib piv, yog tias qhov kev hloov pauv yuav tsum tau taw qhia. mus rau Ω cov ntaub ntawv ntau. Qhov ntsuas tam sim no yuav tsum taw tes rau mA lossis UA.


(4) Xaiv txoj hauj lwm ntawm qhov kev xeem cov hlau lead.


(5) Yuav ua li cas nkag siab txog kev nyeem ntawv ntawm multimeter


Raws li qhov kwv yees tus nqi ntawm Circuit Court nyob rau hauv kev sim, xaiv ib qho chaw tsim nyog. Nco ntsoov tias tus nqi ntsuas los ntawm qhov ntxeev ntawm qhov hloov pauv yog tus nqi sib xws ntawm kev nyeem ntawv puv ntawm rab koob ntawm lub taub hau 'meter'. Thaum nyeem cov 'meter', koj tsuas yog yuav tsum tau hloov nws raws li kev nyeem tus nqi tiag tiag.


Piv txwv li, tus nqi siab tshaj plaws ntawm txhua lub roj teeb qhuav yog 1.5V, yog li nws tuaj yeem muab tso rau hauv 5V ntau yam. Lub sijhawm no, 500 ntawm qhov ntsuas tag nrho ntawm txhais tes ntawm lub vaj huam sib luag yuav tsum tau nyeem raws li 5. piv txwv li scaled los ntawm ib qho ntawm 100. Yog tias rab koob nyob ntawm 300 cim, nws nyeem 3V. Tsuas yog rau qhov kev tiv thaiv ntau yam, txhua qhov kev hloov pauv hloov pauv tuaj yeem nyeem cov txiaj ntsig ntsuas hauv txoj kev no.


Yuav ua li cas siv lub multimeter


1. Ntsuas qhov hluav taws xob: Xaiv qhov zoo tshaj plaws thaum ntsuas qhov hluav taws xob (lossis tam sim no). Yog tias koj siv ntau yam me me los ntsuas qhov hluav taws xob loj, yuav muaj kev phom sij ntawm qhov ntsuas kub; Yog tias koj siv ntau qhov loj los ntsuas qhov voltage me me, tus pointer deflection yog qhov me me dhau los nyeem tau. Kev xaiv ntawm qhov ntau yuav tsum sim ua kom tus pointer deflect mus txog 2/3 ntawm tag nrho cov nplai. Hauv qhov kev ntsuas tiag tiag, thaum kwv yees tus nqi ntawm qhov ntsuas qhov ntsuas tsis tuaj yeem txiav txim siab, qhov hloov pauv tuaj yeem hloov mus rau qhov siab tshaj plaws ua ntej, thiab tom qab ntawd qhov ntau tuaj yeem txo qis ib kauj ruam mus rau txoj haujlwm tsim nyog. Feem ntau, thaum ntsuas qhov hluav taws xob, tus cwj mem ammeter yuav tsum txuas nrog lub voj voog hauv kev sim.


ib. Kev ntsuas ntawm AC voltage: Teem ib qho kev hloov ntawm lub multimeter mus rau AC thiab DC voltage ntau, thiab lwm qhov hloov mus rau qhov tsim nyog ntawm AC voltage, thiab txuas ob lub cwj mem ntawm multimeter mus rau hauv Circuit Court lossis load nyob rau hauv kev sim nyob rau hauv parallel.


b Kev ntsuas ntawm DC voltage: Muab ib qho kev hloov ntawm lub multimeter ntawm AC thiab DC voltage ntau, thiab lwm qhov kev hloov ntawm qhov tsim nyog ntawm DC voltage, thiab txuas cov "ntxiv" xeem lead (liab test lead) mus rau lub peev xwm siab, "-" Cov khoom siv lead ua (cov hmoov txhuas dub) txuas nrog rau qhov tsis muaj peev xwm, uas yog, cia cov dej ntws tam sim no los ntawm qhov "ntxiv" cov hlau lead thiab ntws tawm ntawm qhov "-" cov hlau lead. Yog hais tias qhov kev xeem coj tau thim rov qab, tus pointer ntawm lub ntsuas lub taub hau yuav deflect nyob rau hauv qhov kev taw qhia, thiab nws yooj yim rau khoov tus pointer.


2. Kev ntsuas tam sim no: Thaum ntsuas DC voltage, teem ib qho kev hloov ntawm multimeter mus rau DC tam sim no ntau yam, thiab lwm qhov hloov mus rau qhov tsim nyog ntawm 50uA txog 500mA. Qhov ntau yam xaiv thiab kev nyeem ntawv rau tam sim no yog tib yam li qhov voltage. Lub sijhawm no, kev saib xyuas yuav tsum tau them rau qhov zoo thiab qhov tsis zoo polarities. Yog tias qhov kev xeem coj tau txuas rov qab, txhais tes ntawm qhov kev xeem yuav thim rov qab. Yog tias koj tsis paub qhov zoo thiab qhov tsis zoo ntawm lub voj voog, koj tuaj yeem muab qhov ntau ntawm Wantian meter ntawm qhov siab tshaj plaws, sim nws sai sai rau hauv Circuit Court nyob rau hauv kev sim, thiab saib seb tus cwj mem deflects, koj tuaj yeem txiav txim qhov zoo. thiab tsis zoo polarity. Tsis muaj qhov zoo lossis qhov tsis zoo. Thaum ntsuas, lub Circuit Court yuav tsum raug txiav ua ntej, thiab tom qab ntawd lub multimeter txuas nrog hauv series mus rau hauv Circuit Court nyob rau hauv kev sim raws li cov kev taw qhia ntawm tam sim no los ntawm "ntxiv rau" mus rau "-", uas yog, tam sim no ntws los ntawm cov liab xeem. txhuas thiab ntws tawm los ntawm cov hlau kuaj dub.


Thaum ntsuas DC tam sim no, yog hais tias lub multimeter yog yuam kev nyob rau hauv parallel nrog lub load, lub internal kuj ntawm lub meter taub hau yog heev me me, uas yuav ua rau ib tug luv luv Circuit Court thiab hlawv lub 'meter'. Txoj kev nyeem ntawv yog raws li hauv qab no: tus nqi tiag tiag=qhia tus nqi × ntau yam / tag nrho qhov sib txawv


3. Kev ntsuas qhov tsis kam: Thaum ntsuas qhov tsis kam nrog lub ntsuas ntsuas, yuav tsum ua raws li cov hauv qab no:


ib tug Mechanical xoom hloov kho. Ua ntej siv, koj yuav tsum tau kho lub pointer positioning ntsia hlau ua rau qhov ntsuas tam sim no xoom kom tsis txhob muaj qhov tsis tsim nyog.


b Xaiv cov ntaub ntawv magnification tsim nyog. Qhov ntsuas kab ntawm ohm nplai ntawm multimeter yog qhov tsis sib xws, yog li kev xaiv ntawm qhov ntsuas qhov loj me yuav tsum ua kom tus taw qhia nyob rau ntawm qhov nyias nyias ntawm kab kab, thiab qhov ze ntawm tus taw tes yog mus rau nruab nrab ntawm qhov ntsuas, qhov tseeb dua. kev nyeem ntawv yuav yog. Feem ntau, tus taw tes yuav tsum nyob nruab nrab ntawm 1/3 ~ 2/3 ntawm qhov ntsuas.


c ohm mus zero. Ua ntej ntsuas qhov tsis kam, ob qhov kev xeem coj yuav tsum tau luv luv, thiab "ohm (hluav taws xob) xoom hloov pob qhov rooj" yuav tsum tau kho tib lub sijhawm kom tus pointer tsuas yog taw qhia rau xoom txoj haujlwm ntawm sab xis ntawm ohm. nplai. Yog tias tus pointer tsis tuaj yeem hloov mus rau xoom txoj haujlwm, nws txhais tau hais tias lub roj teeb voltage tsis txaus lossis muaj teeb meem hauv lub ntsuas. Thiab txhua zaus lub iav magnification hloov, lub ohm xoom hloov yuav tsum tau ua dua kom paub meej qhov ntsuas qhov tseeb.


d Kev Nyeem Ntawv: Muab ntau qhov kev nyeem ntawv ntawm lub taub hau ntawm lub 'meter' los ntawm kev nthuav dav, uas yog tus nqi tsis kam ntawm qhov ntsuas tsis kam.


Thaum xub thawj siab ib muag, lub multimeter zoo nkaus li nyuaj, tab sis qhov tseeb nws yog tsim los ntawm ib tug ammeter (feem ntau hu ua lub taub hau meter), ib tug dial, ib tug ntau yam ntawm kev xaiv, thiab xeem coj. Thaum siv, yog tias qhov kev xaiv hloov pauv tau taw qhia rau DC tam sim no ntau yam, lub ammeter M txuas nrog qee qhov shunt resistors nyob rau hauv parallel kom paub lub hom phiaj ntawm kev nthuav dav, ua rau nws yog ammeter nrog ntau yam sib txawv. Kev ntsuas qhov tshwm sim nyob ntawm qhov kev nyeem ntawm DC tam sim no ntsuas ntawm lub dial. Feem ntau cov kab thib ob ntawm lub dial yog qhov ntsuas tam sim no. Ib yam li ntawd, yog tias qhov kev xaiv ntau yam hloov mus rau DC voltage ntau, lub taub hau meter txuas nrog rau lwm cov resistors (siv lub hauv paus ntsiab lus ntawm series resistor voltage division los ua ib tug ntau yam voltmeter). Kev nyeem ntawv yog nyob ntawm qhov ntsuas DC voltage ntawm lub dial. Feem ntau multimeters siv ib qho kev ntsuas rau voltage thiab tam sim no. Yog hais tias lub rectifier txuas nrog lub voj voog rau kev ntsuas DC voltage, AC voltage tuaj yeem ntsuas. Lub hauv paus ntsiab lus ntawm kev ntsuas kev tiv thaiv zoo ib yam li kev ntsuas DC voltage, tshwj tsis yog tias cov roj teeb yuav tsum tau ntxiv thaum lub sijhawm kuaj. Thaum xaiv qhov hloov pauv tau taw qhia rau qhov kev tawm tsam, tsuas yog pom thawj kab ntawm kev tiv thaiv tshwj xeeb ntsuas ntsuas ntawm lub xov tooj.


Kev ceev faj rau kev siv lub multimeter


Muaj ntau cov qauv ntawm multimeters, tab sis cov kev siv yooj yim yog tib yam. Tam sim no coj MF30 multimeter ua piv txwv los qhia txog nws kev siv.


Kev npaj ua ntej siv Ua ntej, ua ntej siv lub multimeter, koj yuav tsum paub txog kev ua haujlwm ntawm ntau yam kev xaiv hloov. Koj xav ntsuas dab tsi? Yuav ntsuas li cas? Tom qab ntawd tig qhov kev xaiv ntau yam hloov mus rau txoj hauj lwm uas yuav tsum tau kuaj iav. Tsis txhob muab lub iav tsis raug. Piv txwv li: Thaum ntsuas qhov voltage, thaum lub selector hloov yog yuam kev rau qhov tam sim no los yog tsis kam, nws yog ib qho yooj yim mus hlawv tawm lub meter taub hau.


Qhov thib ob, xyuas seb lub moos ntawm tes yog xoom ua ntej siv. Yog tias tsis qhia qhov xoom txoj hauj lwm, siv lub hau ntswj los kho cov neeg kho tshuab xoom hloov ntsia hlau ntawm lub taub hau 'meter' kom txhais tes rov qab mus rau xoom (feem ntau, nws tsis tas yuav kho txhua zaus). Cov hlau kuaj liab yuav tsum tau muab tso rau hauv qhov zoo, thiab cov hlau kuaj dub yuav tsum muab tso rau hauv qhov tsis zoo.


Kev ceev faj rau kev siv lub multimeter


Kev ceev faj rau kev siv lub multimeter


(1) Nyob rau hauv tus txheej txheem ntawm kev siv lub multimeter, tsis txhob kov cov hlau ib feem ntawm lub xeem txhuas nrog koj txhais tes, yog li ntawd nyob rau hauv ib tes, qhov tseeb ntawm kev ntsuas yuav tau guaranteed, thiab ntawm qhov tod tes, tus kheej kev nyab xeeb muaj peev xwm. kuj yuav lav.


(2) Thaum siv lub multimeter, nws yuav tsum tau muab tso rau kab rov tav kom tsis txhob ua yuam kev. Nyob rau tib lub sijhawm, kev saib xyuas yuav tsum tau them kom tsis txhob cuam tshuam ntawm sab nraud magnetic teb ntawm multimeter.


(3) Thaum ntsuas qee qhov hluav taws xob, nws tsis tuaj yeem hloov lub zog thaum ntsuas, tshwj xeeb tshaj yog thaum ntsuas qhov hluav taws xob siab lossis siab tam sim no, yuav tsum tau them nyiaj ntau dua. Txwv tsis pub, lub multimeter yuav puas. Yog tias koj xav tau hloov lub zog, koj yuav tsum txiav tawm qhov kev xeem ua ntej, thiab tom qab ntawd ntsuas tom qab hloov lub zog.


(4) Tom qab siv lub multimeter, qhov hloov pauv yuav tsum muab tso rau ntawm qhov siab tshaj plaws ntawm AC voltage. Yog tias nws tsis siv sijhawm ntev, lub roj teeb hauv lub tshuab hluav taws xob yuav tsum tau muab tshem tawm los tiv thaiv lub roj teeb ntawm corroding lwm yam khoom hauv lub ntsuas.


3 Multimeter Digital

Xa kev nug