+86-18822802390

Cov ntsiab lus ntawm Yog vim li cas rau Instability ntawm pH Meter Numbers

Aug 01, 2023

Cov ntsiab lus ntawm Yog vim li cas rau Instability ntawm pH Meter Numbers

 

① Xyuas seb lub electrode puas lawm.


② Nws yuav tsum yog tias cov electrode tau siv ntev dhau lawm. Ua ntej, ntsuas nws kom pom tias nws muaj txiaj ntsig.


③ Koj tuaj yeem sim soaking qhov kev sojntsuam hauv 2.5mmoL / L KCL tov.


④ Ntxuav lub khob iav. Puas yog nws ntev dhau lawm thiab muaj qee cov organic tshuaj txuas nrog rau nws, ua rau cov tshuaj tiv thaiv tsis txaus ntseeg.


⑤ Muaj cov tshuaj sib npaug CO2 ntxiv rau H2O → H ntxiv rau HCO3- hauv dej, thiab vim qhov tsis muaj zog alkalinity ntawm cov dej ntshiab lossis cov dej saum npoo av, qhov sib npaug hloov mus rau qhov zoo ntawm cov tshuaj tiv thaiv, ua rau muaj kev nce ntxiv hauv cov dej. pH.


⑥ Ntxiv cov ntsev nruab nrab (xws li KCL) rau hauv cov qauv dej kuaj raws li Ionic lub zog tswj kom hloov tag nrho cov ionic zog hauv cov tshuaj, nce conductivity, thiab ua rau kev ntsuas ceev thiab ruaj khov. Txoj kev no tau teev tseg nyob rau hauv lub teb chaws tus qauv GB/T6P04.3-93: "Yuav kom txo cov kev cuam tshuam ntawm cov kua hlws ris muaj peev xwm thiab sai ncav cuag stability thaum ntsuas cov qauv dej, ib tug poob ntawm nruab nrab {{ 6}}.1mol/LKCL tov yog ntxiv rau txhua 50ml ntawm cov qauv dej." Txawm hais tias txoj kev no hloov lub zog Ionic hauv cov qauv dej, ua rau pH tus nqi hloov mus rau qee qhov, qhov kev sim qhia tau hais tias qhov kev hloov pauv no tsuas yog hloov pauv ntawm 0.01pH ntawm tus nqi, uas yog qhov ua tau tiav. Tab sis thaum siv txoj kev no, nws tseem ceeb heev uas yuav tsum nco ntsoov tias KCL cov tshuaj ntxiv yuav tsum tsis txhob muaj cov alkaline lossis acidic impurities. Yog li ntawd, KCL reagents yuav tsum yog cov purity siab, thiab cov dej zoo ntawm cov tshuaj npaj yuav tsum yog siab purity nruab nrab dej zoo.


Lub neej ntev npaum li cas ntawm pH electrodes?

Lub neej ntev ntawm pH electrodes muaj feem xyuam rau cov khoom ntawm cov qauv ntsuas, qauv ntsuas kub, zaus ntawm kev siv, thiab kev saib xyuas. Raws li kev siv ib txwm muaj thiab kev saib xyuas kom zoo, pH electrode muaj lub neej ntev ntawm 1 txog 2 xyoos.


Puas yog pH ntsuas qhov tseeb?

Puas yog pH ntsuas qhov tseeb? Tib txoj kev txhim khu kev qha thiab yooj yim tshaj plaws yog siv pH tus qauv tsis haum rau kev ntsuas. Siv peb lub pH qauv tsis daws teeb meem: pH 6.86, pH 4.00, pH 9.18 (nyiam dua tshiab tshiab thiab nyob rau tib qhov kub), ua qhov chaw ntsuas pH 6.86 , nqes hav calibration nrog pH 4. Yog tias qhov tseeb tsis tsim nyog, nws tuaj yeem txiav txim siab ntxiv seb puas muaj teeb meem nrog pH meter lossis pH electrode

 

2 Ph tester -

Xa kev nug