ua ntej ntsuas


Thawj yog kom raug xaiv lub clamp ammeter raws li hom thiab voltage theem ntawm qhov ntsuas tam sim no, thiab qhov voltage ntawm txoj kab ntsuas yuav tsum qis dua qhov ntsuas hluav taws xob ntawm lub ntsuas hluav taws xob. Thaum ntsuas qhov tam sim no ntawm cov kab hluav taws xob high-voltage, yuav tsum xaiv lub high-voltage clamp ammeter uas phim nws qhov voltage theem. Lub clamp ammeter ntawm qib qis voltage tsuas tuaj yeem ntsuas qhov tam sim no hauv qhov hluav taws xob tsis tshua muaj hluav taws xob, thiab tsis tuaj yeem ntsuas qhov tam sim no hauv qhov hluav taws xob siab.


Qhov thib ob yog kom raug kuaj xyuas qhov pom ntawm lub clamp ammeter ua ntej siv. Nco ntsoov xyuas seb qhov rwb thaiv tsev ntawm lub ntsuas hluav taws xob puas zoo, lub plhaub yuav tsum tsis txhob puas, thiab tus kov yuav tsum huv thiab qhuav. Yog hais tias tus pointer tsis nyob zero, ua txhua yam xoom hloov kho. Lub puab tsaig ntawm lub clamp ammeter yuav tsum tau nruj nreem txuas. Yog tias tus pointer shakes, koj tuaj yeem qhib thiab kaw lub puab tsaig dua. Yog tias tseem muaj kev co, ua tib zoo xyuas, ua tib zoo tshem tawm cov sundries thiab av ntawm lub puab tsaig, thiab tom qab ntawd ntsuas.


Txij li thaum lub clamp ammeter nyob rau hauv kev sib cuag nrog kab nyob rau hauv kev sim, lub clamp ammeter tsis tuaj yeem ntsuas qhov tam sim no ntawm tus neeg xyuas pib liab qab. Thaum ntsuas nrog high-voltage clamp meter, nws yuav tsum tau ua los ntawm ob tug neeg. Thaum lub sij hawm ntsuas, cov hnab looj tes insulating yuav tsum tau hnav, sawv ntawm ib qho insulating lev, thiab tsis txhob kov lwm yam khoom siv los tiv thaiv luv luv los yog hauv av.


Thaum ntsuas


Thawj qhov yog nias tus ciaj ntswj kom nruj kom qhib lub puab tsaig, muab cov xaim xaim mus kuaj rau hauv nruab nrab ntawm lub puab tsaig, thiab tom qab ntawd loosen tus ciaj ntswj kom kaw lub puab tsaig kom nruj. Yog tias muaj suab nrov ntawm qhov sib koom ua ke ntawm lub puab tsaig, nws yuav tsum tau qhib thiab kaw dua. Yog tias tseem muaj suab nrov, qhov sib koom ua ke yuav tsum tau kho kom qhov kev nyeem ntawv raug. Tsis tas li ntawd, tsis txhob clamp ob lub xov hlau tib lub sijhawm. Tom qab nyeem ntawv, qhib lub puab tsaig, thim cov hlau ntsuas, thiab teeb lub iav mus rau qhov siab tshaj plaws tam sim no iav lossis OFF iav.


Qhov thib ob, nws yog ib qho tsim nyog los xaiv qhov tsim nyog ntawm lub clamp ammeter raws li qhov loj ntawm qhov ntsuas tam sim no. Qhov kev xaiv yuav tsum yog me ntsis loj dua tus nqi ntawm qhov ntsuas tam sim no. Yog tias nws tsis tuaj yeem kwv yees, txhawm rau tiv thaiv kev puas tsuaj rau lub clamp ammeter, pib ntsuas los ntawm qhov siab tshaj plaws, thiab maj mam hloov lub zog kom txog thaum qhov ntau yam haum. Nws yog nruj me ntsis txwv tsis pub hloov lub iav txoj hauj lwm ntawm lub clamp ammeter thaum lub sij hawm ntsuas. Thaum hloov cov iav, cov hlau ntsuas yuav tsum tau muab tshem tawm ntawm lub puab tsaig ua ntej hloov lub iav txoj hauj lwm.


Thaum ntsuas qhov ntsuas tam sim no tsawg dua 5 amps, txhawm rau ua kom qhov kev nyeem ntawv ntau dua, thaum muaj xwm txheej tso cai, ntsuas qhov ntsuas tam sim no tuaj yeem raug mob ob peb zaug thiab muab tso rau hauv lub puab tsaig rau kev ntsuas. Nyob rau lub sijhawm no, tus nqi tam sim no ntawm cov xaim nyob rau hauv kev sim yuav tsum sib npaug rau qhov kev nyeem ntawv tus nqi ntawm lub 'meter' faib los ntawm cov xov tooj ntawm cov hlau coils muab tso rau hauv lub puab tsaig.


Thaum ntsuas, ua tib zoo saib xyuas kom muaj kev nyab xeeb ntawm txhua qhov ntawm lub cev thiab lub cev them nyiaj. Qhov kev nyab xeeb ntawm qhov hluav taws xob qis yog 0.1 txog 0.3 meters. Thaum ntsuas qhov tam sim no ntawm txhua theem ntawm high-voltage cable, qhov kev ncua deb ntawm lub cable xaus yuav tsum ntau tshaj 300mm, thiab cov rwb thaiv tsev yuav tsum zoo, thiab kev ntsuas tsuas yog nqa tawm thaum nws pom tau tias yooj yim. Thaum soj ntsuam lub sijhawm ntawm lub moos, kev saib xyuas tshwj xeeb yuav tsum tau them rau kev tswj kom muaj kev nyab xeeb ntawm lub taub hau thiab qhov chaw nyob. Qhov kev ncua deb ntawm ib feem ntawm tib neeg lub cev thiab lub cev nyob yuav tsum tsis txhob tsawg tshaj li qhov ntev ntawm lub clamp meter.


Thaum ntsuas qhov tam sim no ntawm cov hluav taws xob tsis tshua muaj hluav taws xob fusible fuses lossis kab rov tav txheej txheem qis-voltage busbars, lub fusible fuses lossis busbars ntawm txhua theem yuav tsum tau tiv thaiv thiab cais nrog cov ntaub ntawv insulating ua ntej ntsuas kom tsis txhob muaj kev cuam tshuam luv luv. Thaum ib theem ntawm cov cable yog grounded, nws yog nruj me ntsis txwv tsis pub ntsuas los tiv thaiv qhov tshwm sim ntawm cov av tawg tawg vim qhov qis rwb thaiv tsev ntawm lub taub hau cable thiab ua rau muaj kev phom sij rau tus kheej.


tom qab ntsuas


Tom qab kev ntsuas tiav, yog tias lub clamp ammeter ntawm lub clamp ammeter yog ntsuas nrog ib qho kev sib nqus magnetoelectric system clamp meter, tus nqi qhia yuav txawv heev ntawm tus nqi tiag tiag los ntsuas, lossis txawm tias tsis muaj qhov qhia tau. Qhov laj thawj yog vim li cas lub tshuab hluav taws xob magnetoelectric Lub taub hau ntawm lub ntsuas hluav taws xob txuas nrog lub kauj thib ob ntawm lub tshuab hluav taws xob, thiab qhov hluav taws xob ntawm lub taub hau 'meter' tau txais los ntawm cov kauj ruam thib ob. Raws li lub hauv paus ntsiab lus ntawm electromagnetic induction, kev sib nrig sib induction electromotive quab yuam yog E2=4.44fWФm. Nws tsis yog qhov nyuaj kom pom los ntawm kev tshaj tawm tias qhov loj ntawm kev sib nrig sib induction electromotive quab yuam yog proportional rau qhov zaus. Thaum hom clamp meter no siv los ntsuas lub rotor tam sim no, vim qhov tsawg zaus ntawm lub rotor, qhov hluav taws xob tau txais ntawm lub taub hau 'meter' yuav tsawg dua qhov voltage thaum ntsuas tib lub zog zaus tam sim no (vim tias hom ntsuas no lub taub hau yog raws li AC 50Hz fais fab zaus tsim). Qee lub sij hawm tam sim no me me uas lub ntsiab lus kho nyob rau hauv lub taub hau 'meter' tsis tuaj yeem tig rau, yog li lub ntsuas ntsuas clamp tsis muaj qhov taw qhia, lossis qhov taw qhia tus nqi txawv ntawm tus nqi tiag tiag.


Yog hais tias lub clamp meter ntawm lub tshuab electromagnetic raug xaiv, txij li lub ntsuas mechanism tsis muaj qhov thib ob coil thiab rectifying element, cov hlau nplaum flux generated los ntawm cov ntsuas tam sim no dhau los ntawm lub taub hau 'meter', magnetizes qhov zoo li qub thiab txav cov hlau ntawm lub taub hau, thiab deflects tus pointer ntawm lub taub hau ' meter ', uas yog raws li qhov ntsuas ntsuas. Qhov zaus ntawm qhov tam sim no tsis muaj teeb meem, yog li tus nqi ntawm lub rotor tam sim no tuaj yeem qhia tau tseeb.


(2) Thaum siv lub clamp ammeter los ntsuas qhov ntsuas peb-theem sib npaug, qhov ntsuas tam sim no tus nqi thaum ob-theem xaim nyob rau hauv lub puab tsaig yog tib yam li qhov ntsuas tam sim no thaum ib theem muab tso rau. Thaum siv lub clamp ammeter los ntsuas qhov ntsuas peb-theem sib npaug, yuav muaj qhov tshwm sim txawv txawv, uas yog, tus nqi qhia thaum ob-theem xaim tso rau hauv lub puab tsaig yog tib yam li tus nqi qhia thaum ib-theem xaim yog muab tso rau hauv, qhov no yog vim hais tias peb-theem sib npaug load Hauv Circuit Court, tus nqi tam sim no ntawm txhua theem yog sib npaug, thiab cov lus qhia hauv qab no yog siv los qhia Iu=Iv=Iw. Yog hais tias ib theem hlau yog muab tso rau hauv lub puab tsaig, lub clamp meter qhia tus nqi tam sim no ntawm theem, thaum ob theem xaim nyob rau hauv lub puab tsaig, tus nqi qhia los ntawm lub 'meter' yog qhov tseeb ntawm cov phasors ntawm ob theem tam sim no, Raws li lub hauv paus ntsiab lus ntawm phasor ntxiv, I1 ntxiv rau I3=-I2, yog li tus nqi qhia tau zoo ib yam li thaum ib theem muab tso rau hauv.


Yog hais tias peb theem yog muab tso rau hauv lub clamp nyob rau tib lub sij hawm, thaum lub load peb-theem yog sib npaug, I1 ntxiv rau I2 ntxiv rau kuv 3=0, uas yog, kev nyeem ntawv ntawm lub clamp ammeter yog xoom.

 