Cov txheej txheem thiab cov txheej txheem rau ntsuas peb -Phase Power Siv Multimeter

Dec 20, 2025

Tso lus

Cov txheej txheem thiab cov txheej txheem rau ntsuas peb -Phase Power Siv Multimeter

 

1. Peb paub tias tsev neeg 220V AC fais fab tuag yog qhov txaus ntshai heev, tsuav nws tsis ncaj qha mus cuag cov hlau xaus, tsis muaj kev phom sij. Kev sib cuag ncaj qha nrog 380V kev lag luam hluav taws xob kuj tseem ceeb heev. Nws 50HZ zaus thiab 380V high voltage ua rau muaj kev phom sij ntau dua rau tib neeg lub cev. Yog li nws yuav tsum paub txog nws cov yam ntxwv thiab cov ntsiab lus siv. Lub ntsiab lus tseem ceeb yog kom tsis txhob kov cov hlau xaus lossis cov khoom hlau nrog tes liab qab txhua lub sijhawm. Vim hais tias peb cov xov hlau ntawm 380V fais fab mov yog tag nrho cov nyob ntawm tej, ib qho kev sib cuag nrog lawv tuaj yeem tsim hluav taws xob txaus ntshai ntawm 220V nrog hauv av. Yog li ntawd, xyuam xim tshwj xeeb rau kev siv hluav taws xob zoo. Ua ntej, paub meej tias cov kev sojntsuam multimeter nyob rau hauv kev sib cuag zoo thiab tig lub multimeter hloov mus rau AC txoj haujlwm.

 

2. Ua ntej, paub meej tias cov kev sojntsuam multimeter nyob rau hauv kev sib cuag zoo thiab tig lub tshuab multimeter hloov mus rau AC txoj haujlwm. Raws li lub hauv paus ntsiab lus ntawm kev siv multimeter los ntawm qhov siab mus rau qis, nws yog kwv yees tias tsis muaj 1KV fais fab mov yuav tsum tau kuaj, yog li xaiv qhov ntau ntawm 500V.

 

3. Rau kev nyab xeeb ntawm kev ua haujlwm, cov neeg tuaj yeem sawv ntawm cov rooj ntoo qhuav lossis cov quav. Ua li no, tib neeg lub cev thiab lub ntiaj teb yog insulated. Yog tias koj tuaj rau hauv kev sib cuag nrog cov hlau nyob ntawm lub tsev ntoo, tsis muaj kev phom sij. Txawm li cas los xij, lub sijhawm no, koj yog qhov txuas ntxiv ntawm cov xaim no thiab tsis tuaj yeem nkag mus rau lwm yam, suav nrog lub ntiaj teb. Yog hais tias kev sib cuag ua ib lub voj voog, nws yog qhov txaus ntshai. Tam sim no nqa lub multimeter los ze zog rau lub hwj chim mov, uas yog, tus contactor. Ob qhov kev sojntsuam ntawm lub multimeter yog nyob rau hauv kev sib cuag nrog ob qhov hlau ntawm contactor, tsis muaj dub probes, U, V, los yog W. Ob kab yog txaus.

 

4. Lub sijhawm no, koj tuaj yeem pom los ntawm lub vaj huam sib luag ntawm multimeter tias tus pointer yog deflected mus rau sab xis thiab nres txav thaum nws mus txog ib qho chaw. Tus nqi no yog qhov voltage ntawm ob kab no. Kev nyeem ntawv zoo li no: ntawm lub vaj huam sib luag ntawm multimeter, muaj V cim nyob rau sab laug kawg ntawm qhov thib ob arc, qhia qhov voltage. Voltage yuav muab faib ua AC thiab DC, uas yog, waveform thiab ncaj kab. Peb ntsuas alternating tam sim no. Tus nqi yog nyob ntawm no arc. Txij li thaum peb siv 500 lub zog thiab qhov ntsuas yog 10, 50, thiab 250, peb suav txhua lub iav los ntawm 5 zaug. Peb 500 yog 10 npaug ntau dua 50, thiab koj tuaj yeem pom tsuas yog 50 scale kab, uas yog raws nraim ntawm tus nqi ntawm 38. Yog li ntawd, ntxiv 10 zaug ntxiv yog 380V. Ib yam mus rau lwm lub zog, yog li koj tuaj yeem nkag siab thiab nyeem cov txiaj ntsig.

 

5. Tom qab ntawd tuav ib tug cwj mem nyob rau hauv tib txoj hauj lwm thiab txuas rau lwm tus cwj mem mus rau lub thib peb hlau. Nws tuaj yeem yog UV, UW, VW.

 

6. Cov txiaj ntsig ntsuas yog tag nrho 380V. Tus yam ntxwv ntawm peb -theem hluav taws xob no yog tias muaj ib theem hluav taws xob ntawm 380V ntawm txhua ob kab, uas kuj yog kab hluav taws xob ntawm 380V. Qhov no yog peb -theem peb xaim fais fab mov hom. Kuj tseem muaj peb -theem plaub xaim, uas muaj cov xaim nruab nrab. Kev sib raug zoo ntawm lawv yog theem voltage lossis 380V, thiab cov xaim nruab nrab yog 220V.

 

7. Ua li no, kuv kawm paub nyeem cov txiaj ntsig ntawm multimeter thiab kuj nkag siab qee yam ntawm peb -theem hluav taws xob.

 

True RMS multimeter digital

Xa kev nug