+86-18822802390

Kev txheeb xyuas cov tshuaj lom thiab cov pa phem

Mar 17, 2023

Kev txheeb xyuas cov tshuaj lom thiab cov pa phem

 

Tam sim no, nrog rau kev tsim cov thev naus laus zis, cov khoom siv roj av kuj yog qhov kev xaiv tshiab rau peb. Txij li thaum lub tshuab ntes no tuaj yeem nruab nrog ntau lub tshuab hluav taws xob (inorganic / organic) ntsuas qhov xav tau ntawm ib tus tswv tsev, nws muaj cov yam ntxwv ntawm qhov me me, lub teeb yuag, cov lus teb ceev ceev, thiab cov roj ntau ntau cov zaub tib lub sijhawm. Qhov tseem ceeb tshaj, tus nqi ntawm lub twj tso kua mis-suction compound gas detector yog pheej yig dua li ntau lub tshuab hluav taws xob ib leeg, thiab nws yooj yim dua los siv. Nws yuav tsum raug sau tseg tias thaum xaiv hom kev ntes no, nws yog qhov zoo tshaj plaws los xaiv ib qho cuab yeej nrog kev ua haujlwm ntawm kev hloov txhua lub sensor sib cais los tiv thaiv kev puas tsuaj ntawm ib lub sensor los ntawm kev cuam tshuam rau kev siv lwm yam sensors. Nyob rau tib lub sijhawm, txhawm rau kom tsis txhob muaj qhov cuam tshuam ntawm lub tshuab nqus dej vim dej nkag, thiab lwm yam, nws muaj kev nyab xeeb dua los xaiv cov cuab yeej tsim nrog lub twj tso kua mis ntse nrog lub twj tso kua mis nres.


Cov teeb meem yuav tsum paub txog thaum siv lub tshuab ntsuas roj:

1) Ua tib zoo saib xyuas qhov cuam tshuam ntawm ntau yam sensors.
Feem ntau hais lus, txhua lub sensor sib raug rau ib qho kev kuaj pom roj, tab sis txhua lub ntsuas roj tsis tuaj yeem hais meej meej. Yog li ntawd, thaum xaiv cov roj sensor, nws yog ib qho tsim nyog yuav tsum nkag siab qhov kev cuam tshuam ntawm lwm cov pa roj rau lub sensor kom ntau li ntau tau, txhawm rau xyuas kom meej tias nws raug kuaj pom cov roj tshwj xeeb.


2) Ua tib zoo saib xyuas qhov ntsuas thiab ntsuas tsis tu ncua.
Cov pa phem thiab cov pa phem, zoo li lwm yam kev ntsuas thiab ntsuas ntsuas, yog ntsuas los ntawm kev sib piv tus txheeb ze: ua ntej, cov pa xoom thiab cov pa roj carbon monoxide yog siv los ntsuas qhov ntsuas, thiab cov qauv nkhaus tau txais thiab khaws cia hauv qhov ntsuas. Thaum lub sij hawm ntsuas, lub ntsuas ntsuas piv cov hluav taws xob teeb liab uas tsim los ntawm cov roj concentration los ntsuas nrog cov hluav taws xob teeb liab ntawm tus qauv concentration, thiab xam qhov tseeb roj concentration tus nqi. Yog li ntawd, zeroing lub ntsuas txhua lub sij hawm thiab nquag calibrating lub ntsuas yog qhov tseem ceeb cov hauj lwm los xyuas kom meej qhov tseeb ntawm lub ntsuas ntsuas. Nws yuav tsum raug sau tseg tias ntau lub tshuab ntes roj tuaj yeem hloov pauv qhov ntsuas ntsuas tam sim no, tab sis qhov no tsis txhais tau tias lub tshuab ntes tuaj yeem nruab nrog cov ntsuas ntsuas sib txawv txhua lub sijhawm. Thaum twg qhov kev sojntsuam raug hloov, lub ntsuas yuav tsum rov ntsuas dua ntxiv rau lub sijhawm ua kom lub sensor. Tsis tas li ntawd, nws raug nquahu kom sim cov lus teb ntawm cov qauv roj siv rau cov ntsuas ua ntej siv los xyuas kom meej tias lub ntsuas ntsuas yeej ua lub luag haujlwm tiv thaiv.


3) Ua tib zoo saib xyuas qhov ntsuas ntsuas qhov ntsuas ntawm qhov ntsuas ntsuas:


Txhua yam tshuaj lom thiab teeb meem roj detectors muaj lawv qhov kev tshawb nrhiav ruaj khov. Tsuas yog thaum qhov ntsuas tau ua tiav nyob rau hauv nws [Industrial Electrical Network-cnelc] kev ntsuas qhov ntsuas tau ntsuas qhov tseeb. Yog tias qhov ntsuas tau ua dhau qhov ntsuas ntsuas tau ntev, nws yuav ua rau muaj kev puas tsuaj mus tas li rau lub sensor.


Piv txwv li, yog tias lub tshuab ntsuas LEL raug siv los ntawm ib puag ncig nrog ntau dua 100 feem pua ​​LEL, nws tuaj yeem hlawv tag nrho lub sensor. Raws li rau cov khoom siv tshuaj lom neeg, nws tseem yuav ua rau muaj kev puas tsuaj yog tias nws siv ntau dua rau lub sijhawm ntev. Yog li ntawd, yog tias lub twj tso kua mis ruaj ruaj xa cov teeb liab dhau qhov kev txwv thaum siv, ntsuas Circuit Court yuav tsum raug muab tua tam sim kom ntseeg tau tias muaj kev nyab xeeb ntawm lub sensor.
Table Concentration nrhiav kom tau ntau yam, daws teeb meem, tso cai concentration thiab siab tshaj plaws tau txais concentration (ppm) ntawm cov pa sensors
Sensor Detection Range Resolution TWA Maximum Concentration Carbon Monoxide 0-5001251500 Hydrogen Sulfide 0-100110500 Sulfur Dioxide 0-200.12150 Nitric Oxide 0-2501251000 Ammonia 0-50125200 Hydrogen Ammonia 0-100110100 Nitrogen 0-100.10.530VOC 0-100000.{11}}Unlimited


4) Ua tib zoo saib lub neej ntawm ntau yam sensors:
Txhua yam ntawm cov pa sensors muaj qee yam kev pab cuam lub neej, uas yog, lub neej. Feem ntau hais lus, hauv cov cuab yeej nqa tau yooj yim, LEL sensors muaj lub neej ua haujlwm ntev dua, uas feem ntau siv tau li peb xyoos; photoionization detectors muaj lub neej ua haujlwm ntawm plaub xyoos lossis ntev dua; Hauv ib mus rau ob xyoos; lub neej ntawm cov pa oxygen sensor yog luv tshaj, txog ib xyoos. Lub neej ntawm electrochemical sensor nyob ntawm qhov dryness ntawm cov electrolyte, yog li yog tias nws tsis siv rau lub sij hawm ntev, sealing nws nyob rau hauv ib tug kub qhov chaw yuav ua rau nws lub neej kev pab cuam. Vim qhov loj me me ntawm cov cuab yeej ruaj khov, lub neej ntawm lub sensor kuj tseem ntev dua. Yog li ntawd, nws yog ib qho tsim nyog los ntsuas lub sensor txhua lub sijhawm, siv nws nyob rau lub sijhawm siv tau ntawm lub sensor ntau li ntau tau, thiab hloov nws lub sijhawm yog tias nws ua tsis tiav.

Nyob rau hauv luv luv, tshuaj lom thiab teeb meem roj detectors yog cov cuab yeej muaj zog los xyuas kom meej muaj kev ruaj ntseg thiab cov neeg ua hauj lwm noj qab haus huv. Peb yuav tsum xaiv lub ntsuas roj kom tsim nyog raws li kev siv ib puag ncig thiab kev ua haujlwm uas yuav tsum tau ua. Tam sim no, cov khoom kuaj pom muaj rau peb suav nrog kev ruaj khov / txav tau yooj yim, diffusion / twj tso kua mis, ib qho roj / multi-gas, inorganic gas / organic gas thiab ntau lwm yam ua ke. Tsuas yog los ntawm kev xaiv cov cuab yeej ntsuas roj tsim nyog tuaj yeem ua tiav ob zaug qhov txiaj ntsig nrog ib nrab ntawm kev siv zog thiab tiv thaiv teeb meem ua ntej lawv tshwm sim.

 

7 Natural gas leak detector

Xa kev nug