1. Muaj tseeb RMS/Average Response
Qhov tseeb RMS txhais tau hais tias ntawm ib qho zaus (xws li lub zog zaus), yog tias qhov loj / qhov loj ntawm qhov hloov pauv tam sim no zoo heev, qhov tseeb RMS raug xam raws li qhov sib xyaw ua ke algorithm simulation, thiab qhov hloov pauv tam sim no tuaj yeem ntsuas. Qhov nruab nrab RMS yog xam raws li qhov nruab nrab tus nqi ntawm lub ncov tus nqi ntawm sine yoj, thiab nws yog ib qho nyuaj rau tso saib qhov ntau tshaj qhov tseeb.
Cov khoom uas muaj tseeb RMS clamp meter: Fluke 319/381/365/369/902FC, thiab lwm yam.
2. Kev daws teeb meem thiab ntau yam
Kev daws teeb meem thiab precision yog 2 lub tswv yim. Los ntawm tus neeg siv qhov kev xav, kev daws teeb meem yog hais txog qhov tsawg kawg nkaus ntawm kev hloov pauv hauv lub teeb liab tos tam sim no uas lub ntsuas ntsuas tuaj yeem txheeb xyuas. Thiab feem ntau nws yog ib qho tsim nyog los muab cov khoom tsim nyog txhawm rau ua kom pom tus nqi ntau dua, lossis ua kom qhov tseeb tshaj plaws ntawm qhov ntsuas ntawm tes.
Piv txwv li, piv txwv tias qhov tam sim no yuav tsum ntsuas yog 2.0A, qhov kev hloov pauv tam sim no yog ntxiv rau /- 0.03A, thiab 2 clamp meters tau suav tias yog: tib yam 1 feem pua qhov tseeb ntxiv 5 tus lej, tib tus lej tso saib; Table 1 (kev daws teeb meem 0.1A, ntau yam 600A), Table 2 (kev daws teeb meem 0.01A, ntau yam 3A). tab sis:
Table 1 tsis tuaj yeem txheeb xyuas qhov hloov pauv tam sim no ntawm 0.03A, thiab kev nyeem ntawv yuav tsis hloov pauv ntawm 2.5A.
Table 2 tuaj yeem txheeb xyuas qhov kev hloov pauv tam sim no ntawm 0.03A, suav nrog 5- tus lej nyeem ntawv raug, qhov kev nyeem ntawv hloov pauv yuav nyob ntawm 1.965-2.035 (qhov ntxiv /{{7}) }.02 qhov tseeb ntau yam tsis tau txiav txim siab).
3. Zaus teb
Tus qauv ua haujlwm tam sim no yog lub zog zaus, yog li feem ntau cov khoom siv clamp meter tau tsim thiab ntsuas raws li lub zog zaus teb. Hauv ib puag ncig sib txawv, muaj qhov sib txawv zaus. Piv txwv li, siv dav siv inverter / VFD muaj ntau zaus ua haujlwm ntawm 30 ~ 50Hz. Lub sijhawm no, yog tias koj xav tau kom raug ntsuas VFD cov zis tam sim no, koj yuav tsum xav txog cov lus teb zaus ntawm lub ntsuas ntsuas clamp.
Cov lus qhia tshwj xeeb ntawm cov khoom lag luam:
Hauv hom kev ua haujlwm ntawm Fluke 381 annotation raug, nws txhawb nqa mus rau 10Hz
4. Low-pass lim
Thaum nws los txog rau zaus, peb yuav tsum hais txog qhov qis dhau lim (LPF). Ntau lub loops yeej cuam tshuam los ntawm high-frequency harmonics, uas tej zaum yuav ua rau lub teeb liab ntsuas los ntawm lub clamp meter siab tshaj tus nqi tiag tiag. Xws li rectifiers, inverters, thiab lwm yam. Yog li ntawd, lub voj voog ntsuas ntawm cov khoom siv no yuav tsum tau siv lub ntsuas ntsuas clamp nrog lub lim dej qis.