Yuav ua li cas xaiv qhov ntau ntawm multimeter thiab tsom xam ntawm kev ntsuas qhov yuam kev

Apr 22, 2023

Tso lus

Yuav ua li cas xaiv qhov ntau ntawm multimeter thiab tsom xam ntawm kev ntsuas qhov yuam kev

 

Yuav muaj qee qhov yuam kev thaum ntsuas nrog multimeter. Qee qhov yuam kev no yog qhov kev ntsuas siab tshaj plaws uas tau tso cai los ntawm chav kawm raug ntawm lub ntsuas nws tus kheej. Qee qhov yog tib neeg yuam kev los ntawm kev hloov kho thiab siv tsis raug. Ua kom nkag siab cov yam ntxwv ntawm multimeter thiab qhov ua rau ntsuas qhov yuam kev, thiab paub txog cov txheej txheem ntsuas thiab cov txheej txheem kom raug, koj tuaj yeem txo qhov ntsuas qhov yuam kev.


Tib neeg kev nyeem ntawv yuam kev yog ib qho laj thawj uas cuam tshuam rau kev ntsuas qhov tseeb. Nws yog kev zam tsis tau tab sis tuaj yeem txo qis. Yog li ntawd, tshwj xeeb yuav tsum tau them rau cov ntsiab lus hauv qab no thaum siv: 1. Ua ntej ntsuas, tso lub multimeter horizontally thiab ua txhua yam xoom hloov kho; 2. Thaum nyeem ntawv, lub qhov muag yuav tsum tau muab tso rau hauv perpendicular rau lub pointer; Thaum qhov kev hloov kho tsawg dua xoom, hloov nrog lub roj teeb tshiab; 4. Thaum ntsuas kev tiv thaiv los yog siab voltage, tsis txhob pinch cov hlau ib feem ntawm cov hlau lead nrog koj txhais tes, thiaj li tsis txhob shunting ntawm tib neeg lub cev tsis kam, nce kev ntsuas yuam kev los yog hluav taws xob poob siab; Txiav tawm lub hwj huam mov hauv Circuit Court, thiab tso tawm cov hluav taws xob khaws cia hauv lub capacitor ua ntej ntsuas. Tom qab tsis suav nrog tib neeg kev nyeem ntawv yuam kev, peb ua qee qhov kev soj ntsuam ntawm lwm qhov yuam kev.


1. Multimeter voltage, tam sim no ntau yam xaiv thiab ntsuas qhov yuam kev


Cov qib raug ntawm multimeters feem ntau muab faib ua ntau qib xws li {{0}}.1, 0.5, 1.5, 2.5, thiab 5. Rau DC voltage, tam sim no, AC voltage, tam sim no, thiab lwm yam., calibration ntawm qhov raug (qhov tseeb) theem yog qhia los ntawm feem pua ​​​​ntawm qhov siab tshaj qhov yuam kev △X thiab tag nrho cov nqi ntawm qhov kev xaiv. Qhia los ntawm cov mis: A feem pua ​​=(△X/tag nrho tus nqi) × 100 feem pua ​​... 1


(1) Siv lub tshuab multimeter nrog qhov tseeb sib txawv los ntsuas qhov yuam kev tsim los ntawm tib qhov hluav taws xob


Piv txwv li: Muaj 10V tus qauv voltage, thiab nws yog ntsuas nrog ob multimeters nrog 100V iav, 0.5 qib thiab 15V qib, 2.5 qib. Lub 'meter' twg muaj qhov ntsuas qhov yuam kev tsawg tshaj plaws?


Kev daws: Los ntawm cov mis 1, peb tau txais: ** thaiv meter ntsuas: * siab kawg ** tso cai yuam kev


△X{{0}}±{5}}.5 feem pua ​​× 100V=±0.50V.


△X{{0}}± 2.5% ×l5V=± 0.375V.


Muab piv △X1 thiab △X2, nws tuaj yeem pom tias txawm tias qhov tseeb ntawm thawj lub moos yog siab dua li ntawm ob lub moos, qhov yuam kev uas tsim los ntawm kev ntsuas ntawm thawj lub moos yog qhov loj dua qhov yuam kev uas tsim los ntawm kev ntsuas thib ob. saib. Yog li ntawd, nws tuaj yeem pom tias thaum xaiv ib lub multimeter, qhov siab dua qhov tseeb, qhov zoo dua. Nrog ib tug multimeter nrog cov neeg siab, nws yog ib qho tsim nyog yuav tau xaiv qhov tsim nyog. Tsuas yog los ntawm kev xaiv qhov tseeb ntau tuaj yeem coj qhov tseeb ntawm multimeter tuaj yeem ua si.


(2) Qhov yuam kev tshwm sim los ntawm kev ntsuas tib qhov hluav taws xob nrog ntau qhov sib txawv ntawm multimeter


Piv txwv li: MF-30 multimeter, nws qhov tseeb yog 2.5, xaiv 100V iav thiab 25V iav los ntsuas 23V tus qauv voltage, lub iav twg muaj qhov yuam kev me dua?


Kev daws: 100V thaiv qhov siab tshaj plaws ntsuas qhov yuam kev:

X(100) =± 2.5% × 100V= ± 2.5V.

Qhov siab tshaj plaws kev ntsuas qhov yuam kev rau 25V iav: △X(25)=± 2.5% × 25V=±0.625V. Nws tuaj yeem pom los ntawm cov kev daws teeb meem saum toj no tias:


Siv 100V thaiv los ntsuas 23V tus qauv voltage, thiab qhov taw qhia ntawm lub multimeter yog nyob nruab nrab ntawm 20.5V-25.5V. Siv lub 25V thaiv los ntsuas 23V tus qauv voltage, thiab qhov taw qhia ntawm lub multimeter yog nyob nruab nrab ntawm 22.375V{10}}.625V. Los ntawm cov txiaj ntsig saum toj no, △X(100) ntau dua △X(25), uas yog, qhov yuam kev ntawm 100V thaiv kev ntsuas yog loj dua li ntawm 25V thaiv kev ntsuas. Yog li ntawd, thaum lub multimeter ntsuas qhov sib txawv voltages, qhov yuam kev uas tsim los ntawm ntau yam sib txawv. Nyob rau hauv rooj plaub ntawm kev sib ntsib tus nqi ntawm lub teeb liab yuav tsum tau ntsuas, lub iav nrog qhov ntsuas qhov tsawg tshaj plaws yuav tsum tau xaiv ntau npaum li qhov ua tau. Qhov no nce qhov tseeb ntawm qhov ntsuas.

(3) Qhov yuam kev tshwm sim los ntawm kev ntsuas ob qhov sib txawv ntawm qhov sib txawv ntawm qhov sib txawv ntawm ib qho multimeter


Piv txwv li: MF-30 multimeter, nws qhov tseeb yog 2.5, siv 100V thaiv los ntsuas tus qauv voltage ntawm 20V thiab 80V, qhov thaiv twg muaj qhov yuam kev me dua?


Kev daws: Qhov siab tshaj qhov yuam kev: △A feem pua ​​=Qhov siab tshaj qhov yuam kev △X / ntsuas tus qauv voltage hloov × 100 feem pua, qhov siab tshaj qhov yuam kev ntawm 100V iav △X(100)=± 2.5 feem pua ​​× 100V=± 2.5V.


Rau 20V, nws qhov taw qhia tus nqi yog nyob nruab nrab ntawm 17.5V-22.5V. Qhov siab tshaj qhov txheeb ze yuam kev yog: A(20) feem pua ​​=(± 2.5V/20V) × 100 feem pua ​​=± 12.5 feem pua ​​.


Rau 80V, nws qhov taw qhia tus nqi yog nyob nruab nrab ntawm 77.5V-82.5V. Nws qhov siab tshaj qhov txheeb ze yuam kev yog:


A(80) feem pua ​​=±(2.5V/80V) × 100 feem pua ​​=±3.1 feem pua ​​.


Muab piv rau qhov kev txheeb ze tshaj plaws ntawm qhov ntsuas qhov ntsuas hluav taws xob 20V thiab 80V, nws tuaj yeem pom tau tias qhov yuam kev ntawm qhov qub yog qhov loj dua qhov tom kawg. Yog li ntawd, thaum siv tib yam ntawm ib tug multimeter los ntsuas ob qhov sib txawv voltages, leej twg nyob ze rau tag nrho cov nqi yuav muaj ntau dua. Yog li ntawd, thaum ntsuas qhov ntsuas hluav taws xob, ntsuas qhov ntsuas hluav taws xob yuav tsum tau qhia saum toj 2/3 ntawm lub ntsuas ntsuas qhov ntau. Tsuas yog nyob rau hauv txoj kev no tuaj yeem txo qhov kev ntsuas yuam kev.


2. Kev xaiv ntau yam thiab ntsuas qhov yuam kev ntawm hluav taws xob thaiv


Txhua qhov kev tiv thaiv hluav taws xob tuaj yeem ntsuas qhov ntsuas tus nqi ntawm 0 mus rau ∞. Qhov ntsuas ntsuas ntawm ib qho ohmmeter yog qhov tsis-linear, tsis sib xws, inverted scale. Nws yog qhia raws li ib feem pua ​​ntawm lub arc ntev ntawm lub teev. Tsis tas li ntawd, qhov kev tiv thaiv sab hauv ntawm txhua qhov sib npaug yog sib npaug ntawm qhov sib npaug ntawm qhov nruab nrab ntawm tus lej ntawm qhov ntev ntawm qhov ntsuas, uas yog hu ua "central resistance". Qhov ntawd yog hais tias, thaum ntsuas qhov kev tiv thaiv yog sib npaug rau qhov chaw tiv thaiv ntawm qhov kev xaiv, qhov tam sim no ntws hauv Circuit Court yog ib nrab ntawm tag nrho cov ntsuas tam sim no. Tus pointer qhia qhov nruab nrab ntawm qhov ntsuas. Nws qhov tseeb yog qhia los ntawm cov qauv hauv qab no:


R feem pua ​​=(△R/center resistance) × 100 feem pua ​​……2


(1) Thaum siv multimeter los ntsuas tib qhov kev tiv thaiv, qhov yuam kev tshwm sim los ntawm kev xaiv qhov sib txawv


Piv txwv li: MF{{0}} multimeter, lub hauv paus tsis kam ntawm Rxl0 thaiv yog 250Ω; lub hauv paus tsis kam ntawm Rxl 00 thaiv yog 2.5kΩ. Chav kawm raug yog 2.5. Siv nws los ntsuas 500Ω tus qauv tsis kam, thiab nug seb puas siv R × l0 iav los yog R × 100 iav los ntsuas, qhov yuam kev loj dua? Kev daws: Los ntawm formula 2:


R × l 0 thaiv qhov siab tshaj plaws qhov yuam kev △R(10)= nruab nrab tsis kam × R feem pua ​​=250Ω × (± 2.5) feem pua ​​=± 6.25Ω. Siv nws los ntsuas 500Ω tus qauv tsis kam, ces tus nqi qhia ntawm 500Ω tus qauv tsis kam yog nyob nruab nrab ntawm 493.75Ω{13}}.25Ω. Qhov siab tshaj qhov txheeb ze yuam kev yog: ± 6.25÷500Ω × 100 feem pua ​​=± 1.25 feem pua.


Qhov siab tshaj qhov yuam kev ntawm R × l 00 thaiv △R (100)=nruab nrab tsis kam × R feem pua ​​​​2.5kΩ × (± 2.5) feem pua ​​=± 62.5Ω. Siv nws los ntsuas 500Ω tus qauv tsis kam, ces tus nqi qhia ntawm 500Ω tus qauv tsis kam yog nyob nruab nrab ntawm 437.5Ω{14}}.5Ω. Qhov siab tshaj qhov txheeb ze yuam kev yog: ± 62.5÷500Ω × 100 feem pua ​​=± 10.5 feem pua.


Kev sib piv ntawm cov txiaj ntsig ntawm kev suav qhia tau hais tias qhov ntsuas qhov yuam kev sib txawv heev thaum xaiv qhov sib txawv ntawm qhov sib txawv. Yog li ntawd, thaum xaiv lub iav ntau yam, sim ua kom ntsuas qhov ntsuas qhov ntsuas nyob hauv nruab nrab ntawm qhov ntev ntawm qhov ntsuas qhov ntsuas. Qhov ntsuas qhov tseeb yuav siab dua.

 

2 Multimeter True RMS -