Ib tug multimeter ntsuas tus nqi loj resistors li cas? Kev ceev faj rau kev ntsuas loj kuj nrog multimeter
Yuav ua li cas ntsuas qhov kev tiv thaiv loj nrog lub multimeter, txoj kev thiab cov piv txwv ntawm kev ntsuas loj tsis kam nrog lub multimeter, thiab kev ceev faj rau kev ntsuas qhov loj tsis kam nrog multimeter. Thaum ntsuas qhov tsis kam nrog tus nqi tiv thaiv ntau dua 100MΩ, qhov ntsuas qhov yuam kev yuav nce ntau. Qhov no yuav tsum tau muab sau tseg.
Multimeter ntsuas tus nqi loj resistors
Qhov siab tshaj plaws ntawm qhov kev tiv thaiv ntau yam ntawm 31/2- lej thiab 41 / 2-digit digital multimeters feem ntau yog 20MΩ.
Rau 31/2-digit digital multimeter, siv qhov sib txawv ntawm qhov sib txawv tsuas tuaj yeem ntsuas qhov tsis kam ntawm qhov ntau ntawm 0.1Ω-19.99MΩ; rau ib tug 41/2-digit digital multimeter, nws tsuas yog ntsuas tsis kam nyob rau hauv qhov ntau ntawm 0.01Ω{10}}.999MΩ kuj. Thaum qhov ntsuas tsis kam Rx Ntau dua lossis sib npaug rau 20MΩ, lub ntsuas ntsuas yuav tso tawm cov cim hla "1".
Cov kev sim tau ua pov thawj tias qhov ntau ntawm 20MΩ tsis kam ntau ntawm 31 / 2- lej lossis 41 / 2- lej digital multimeter tuaj yeem txuas ntxiv mus rau 100MΩ los ntawm kev siv cov hauv qab no "txoj kev sib piv".
1. Kev ntsuas ntsuas
Npaj ib qho kev tiv thaiv R1 ntawm ntau tshaj kaum megohms ua ntej, tig lub digital multimeter mus rau 20MΩ ntau, ntsuas tus nqi tsis kam R1, tom qab ntawd txuas qhov ntsuas ntsuas Rx nyob rau hauv qhov sib npaug rau ob qho kawg ntawm R1, thiab tom qab ntawd ntsuas tag nrho cov kev sib piv R.
2. Kev ntsuas piv txwv
Qhov kev tiv thaiv yuav tsum tau sim yog ib tug high-resistance Rx nrog ib tug tsis paub kos npe rau, thiab R1 xaiv ib tug resistor nrog ib tug nominal kuj nqi ntawm 10MΩ. Siv cov ntaub ntawv 20MΩ tsis kam ntawm digital multimeter, ntsuas qhov ntsuas tsis kam ntawm R1 yog 10.05MΩ.
Tom qab txuas Rx thiab R1 nyob rau hauv parallel, ntsuas dua, thiab tag nrho cov nqi tiv thaiv R=7.70MΩ yog ntsuas. Hloov mus rau hauv cov qauv (4-13) kom tau
Judging los ntawm qhov no, tus nqi nominal ntawm qhov ntsuas kuj yuav tsum yog 33MΩ.
3. Ceev faj rau kev ntsuas
1. Thaum tus nqi tsis kam ntawm qhov ntsuas tsis kam Rx tshaj 100MΩ, tag nrho cov nqi tiv thaiv R tom qab kev sib txuas yog ze heev rau tus nqi tsis kam ntawm tus qauv xaiv R1, thiab cov multimeter nws tus kheej muaj qhov yuam kev ntawm ± 1 cim, uas yuav nce qhov kev ntsuas yuam kev. loj.
Yog li, txoj kev no tsis haum rau kev ntsuas kev tiv thaiv ntau dua 100MΩ.
2. Thaum lub sijhawm ntsuas kev ua haujlwm, ntsuas qhov ntsuas tsis kam Rx thiab tus qauv tsis kam R1 yuav tsum tau txuas nrog kev sib txuas thiab ruaj khov. Yog tias tsim nyog, ob qho tib si tuaj yeem kho nrog crocodile clips.