Hluav taws xob cua sov raj tham txog infrared tus pas ntsuas kub infrared ntsuas qhov ua tau zoo
Hluav taws xob cua sov raj tham txog infrared tus pas ntsuas kub infrared ntsuas qhov ua tau zoo
Infrared tus pas ntsuas kub yog los ntawm kev txais tos ntawm lub hom phiaj khoom emission, xav txog thiab conduction ntawm lub zog los ntsuas nws qhov kub thiab txias. Cov khoom kuaj pom nyob rau hauv pyrometer xa cov ntaub ntawv hluav taws xob sib sau mus rau microprocessor rau kev ua haujlwm thiab tom qab ntawd hloov nws mus rau qhov ntsuas kub nyeem rau cov zaub. Nyob rau hauv cov qauv nrog ib tug laser pom, lub laser pom yog siv rau aiming xwb. Nws qhov kev ua tau zoo tau piav qhia nyob rau hauv Table 1.PT, TI series ntawm cov ntsuas ntsuas qhov ntsuas qhov ntsuas tau tsim los ntawm Beijing Infrared Times Kev ntsuas qhov ntsuas kub ntawm -20 degree - 400 degree Zaub daws teeb meem 0.1 degree (<199.1 ℃ when )
Qhov tseeb ± 1% ntawm 23 degree Ua haujlwm ambient kub ntau yam 0--50 degree
Repeatability ± 1% ntawm 23 degree txheeb ze humidity 10-95% ntawm 30 degree
Lub sij hawm teb 500ms Fais fab mov 9V
Teb spectrum 7 -18micron Dimensions 137 × 41 × 196mm
Tus nqi siab tshaj plaws muaj qhov hnyav 270g
Emissivity 0.95Preset
Table 1 Infrared Thermometer Performance Yuav kom tau txais qhov ntsuas kub, qhov kev ncua deb ntawm tus pas ntsuas kub thiab lub hom phiaj ntsuas yuav tsum nyob rau hauv qhov tsim nyog, qhov thiaj li hu ua "spot size" (spot size) yog thaj tsam ntawm tus pas ntsuas kub ntsuas qhov taw tes. Qhov ntxiv deb koj nyob ntawm lub hom phiaj, qhov loj ntawm qhov chaw yuav yog. Qhov piv ntawm qhov deb mus rau qhov chaw loj, lossis D: S, yog siv.
(1) Cov yam ntxwv ntawm cov ntsuas kev ua tau zoo, xws li qhov kub thiab txias, qhov loj me, kev ua haujlwm wavelength, ntsuas qhov tseeb, qhov rais, tso saib thiab tso zis, lub sijhawm teb, cov khoom siv tiv thaiv, thiab lwm yam.; thiab
(2) Ib puag ncig thiab kev ua haujlwm, xws li ambient kub, qhov rais, tso saib thiab tso zis, tiv thaiv accessories, thiab lwm yam .; thiab
(3) Lwm yam kev xaiv, xws li kev siv yooj yim, kev saib xyuas thiab kev ntsuas kev ua haujlwm thiab tus nqi, thiab lwm yam, kuj muaj qee yam cuam tshuam rau kev xaiv ntawm pyrometer.
Nrog rau kev siv thev naus laus zis thiab kev txhim kho tas mus li, tus pas ntsuas kub infrared zoo tshaj plaws tsim thiab kev txhim kho tshiab rau cov neeg siv los muab ntau yam kev ua haujlwm thiab ntau lub hom phiaj, nthuav kev xaiv. Lwm yam kev xaiv, xws li kev yooj yim ntawm kev siv, txij nkawm thiab calibration kev ua tau zoo thiab tus nqi. Hauv kev xaiv cov qauv pyrometer yuav tsum xub txiav txim siab qhov ntsuas qhov xav tau, xws li ntsuas lub hom phiaj ntsuas kub, ntsuas lub hom phiaj loj, ntsuas qhov deb, ntsuas cov khoom siv, lub hom phiaj ib puag ncig, teb ceev, ntsuas qhov tseeb, nrog portable lossis online thiab lwm yam. ; nyob rau hauv ntau yam uas twb muaj lawm qauv ntawm pyrometer sib piv, xaiv kom tau raws li cov saum toj no cov kev cai ntawm lub ntsuas qauv; nyob rau hauv ntau cov qauv uas tuaj yeem ua tau raws li cov kev xav tau saum toj no los xaiv tawm hauv kev ua tau zoo, nta thiab tus nqi ntawm * qhov zoo tshaj plaws match.