Muab tso ua ke ntawm cov teeb meem tshwm sim hauv kev siv txheej thickness gauges
1. Vim li cas lub thickness ntsuas tsis tuaj yeem tig dua tom qab tsis siv rau ib xyoos?
Teb: Thaum cov neeg siv tau txais cov khoom siv tshiab tshiab, lawv thawj zaug yuav tsum tau them tus nqi ntsuas. Feem ntau, nws yuav siv sij hawm 8 teev los them. Yog tias lub roj teeb ntsuas tsis tau them lossis tawm mus ntev, nws yooj yim rau lub ntsuas hluav taws xob kaw, thiab lub roj teeb lub neej yuav cuam tshuam. Rau lub tshuab tshiab uas tsis tau siv rau 2 lub hlis, qhov tshwm sim ntawm kev tsis tuaj yeem pib tuaj yeem yog vim lub roj teeb kaw, uas yuav tsum tau qhib kom ua raws li cov lus qhia. Yog tias lub tshuab tseem tsis tuaj yeem qhib, thov tsis txhob tig rau koj tus kheej thiab rov qab mus rau qhov chaw kho mob kom kho.
2. Lub roj teeb yuav tsum rov qab li cas tom qab kaw?
Teb: Tom qab lub roj teeb kaw lawm, cov neeg siv tuaj yeem xa mus rau cov qauv coj los siv thiab ua haujlwm los ntawm kev yuam kom rov pib dua. Thaum muaj cov ntawv nyeem lossis cov lej qhia, lub roj teeb tuaj yeem them tam sim. Yog tias nws tseem tsis tuaj yeem rov qab tau, thov hu rau lub chaw saib xyuas.
3. Kuv yuav tsum xyuam xim rau dab tsi tom qab kev teeb tsa lub Hoobkas?
Teb: Tom qab qhov yuam kev rov pib dua, qhov ntsuas yuav tsum tau ua raws li qhov yooj yim calibration. Txoj kev calibration tuaj yeem ua tau raws li phau ntawv qhia lossis sab laj nrog cov neeg muag khoom thiab kev saib xyuas thaum lub sijhawm.
4. Vim li cas qhov kev ntsuas ntawm lub workpiece tseem qhia tias "tsis raug" tom qab calibration ntawm randomly txuas calibration xeem daim?
Teb: Muaj ntau yam uas cuam tshuam rau tus nqi ntsuas, uas tau piav qhia hauv cov lus qhia. Cov khoom ntawm cov ntaub ntawv hlau, nto roughness, thiab lwm yam muaj feem cuam tshuam rau tus nqi ntsuas. Qhov sib txuas nrog cov substrate feem ntau muaj qhov sib txawv ntawm cov hlau substrate ntawm tus neeg siv lub xaib. Yog li ntawd, peb xav hais tias randomly coj substrate thiab xeem tej daim yuav tsum tsuas yog siv rau calibration ntsuas. Nyob rau hauv qhov tseeb ntawm qhov chaw ntsuas ntawm workpieces, tib yam khoom uas tsis tau txau rau ntawm qhov chaw yuav tsum tau siv raws li substrate.
5. Dab tsi yog vim li cas rau cov lus yuam kev nrog lub npe 'E' thaum pib?
Teb: Qhov kev ua yuam kev tam sim no yog ib qho tshwj xeeb ntawm cov txheej txheej thickness gauge nyob rau hauv lub era, uas yog yooj yim rau cov neeg siv los piav txog qhov txhaum. Cov lus yuam kev sib txawv sawv cev rau qhov sib txawv, xws li E02 sawv cev hnav ntawm lub taub hau ntsuas. Cov lus qhia no tau piav qhia hauv cov lus rau kev siv.
6. Yuav ua li cas kaw TT220?
Teb: Lub thickness gauge txais yuav tsis siv neeg kaw, feem ntau yog 3-5 feeb tom qab siv.
7. Yuav ua li cas los txiav txim seb lub thickness gauge yog tag nrho them yam tsis muaj lub charger qhia lub teeb?
Teb: Lub sij hawm them nyiaj rau lub ntsuas thickness feem ntau yog 8 teev rau cov cav tov tshiab, thiab 2-3 teev rau kev siv ib txwm.
8. Lub thickness ntsuas yog nruab nrog F / N dual sojntsuam. Yuav tsum calibration yuav tsum tau ua nyias, los yog yuav tsum tau ib tug sojntsuam calibrated?
Teb: Lub sij hawm thickness gauge tau calibrated thaum nws tawm los. Cov neeg siv yuav tsum tsis yooj yim calibrate lub ntsuas. Yog tias muaj qhov sib txawv tseem ceeb, calibration tuaj yeem ua tau raws li kev qhia ntawm Times muag lossis cov neeg siv kev pabcuam. Cov cuab yeej nruab nrog F / N dual lub hom phiaj sojntsuam yuav tsum tau ntsuas nyias.
9. Vim li cas ho tsis tuaj yeem ntsuas lub thickness qee zaum txiav txim siab lub substrate?
Teb: Lub Sijhawm TT210 txheej thickness gauge yog ib qho kev sib xyaw ua ke rau ob qho tib si hlau thiab cov ntawv tsis yog hlau. Nws txais yuav hom kev lag luam suav suav thiab tuaj yeem txheeb xyuas lub substrate. Txawm li cas los xij, muaj ntau txoj kev xaiv hauv cov ntawv qhia zaub mov, suav nrog "automatic", "magnetic", thiab "eddy tam sim no". Tsuas yog los ntawm kev xaiv hom "automatic" tuaj yeem txheeb xyuas qhov substrate