+86-18822802390

Calibration txheej txheem ntawm yaj oxygen meter rau kev saib xyuas dej zoo

Oct 31, 2023

Calibration txheej txheem ntawm yaj oxygen meter rau kev saib xyuas dej zoo

 

Cov ntsiab lus ntawm cov pa oxygen yaj hauv dej yog ib qho ntawm cov cim tseem ceeb los ntsuas lub zog ntawm tus kheej ntawm cov dej thiab txiav txim siab qhov zoo ntawm cov dej. Cov ntsiab lus ntawm cov pa oxygen dissolved yog ze ze rau qhov muaj pes tsawg leeg thiab kev faib tawm ntawm cov zej zog lom neeg hauv cov dej. Rau cov ntses hauv dej, cov pa oxygen yaj yuav tsum muaj ntau dua 4 mg / L kom ntseeg tau tias lawv lub neej ua haujlwm li qub. Yog li ntawd, thaum lub sij hawm saib xyuas cov dej zoo, cov qib siab ntawm kev mloog yog them rau qhov ntsuas ntawm cov pa oxygen yaj.


Cov txheej txheem tseem ceeb rau kev ntsuas cov pa oxygen hauv dej yog: iodometric method, electrochemical probe method, conductivity method thiab fluorescence method. Iodometry yog txoj kev ntxov tshaj plaws siv los ntsuas cov pa oxygen hauv dej thiab tseem yog txoj hauv kev ntsuas ntsuas cov pa oxygen hauv dej. Thaum cov dej muaj qee cov tshuaj txo qis xws li sodium nitrite, sulfide, thiourea, humic acid lossis tannin, nws yuav ua rau muaj kev cuam tshuam ntau dua rau cov ntaub ntawv iodometric titration. Hauv qhov no, cov txheej txheem electrochemical sojntsuam raug pom zoo. . Electrochemical sojntsuam txoj kev ntsuas yog siv dav hauv kev ua haujlwm vim lawv qhov ntsuas ceev ceev, cov txiaj ntsig ruaj khov, cov ntaub ntawv raug, thiab kev cuam tshuam tsawg. Nws txoj hauv kev ua haujlwm yog tias thaum oxygen molecules hauv dej dhau los ntawm lub diaphragm, lawv raug txo los ntawm kev ua haujlwm electrode. Cov txheej txheem no ua kom muaj cov pa oxygen ncaj qha cuam tshuam nrog cov diffusion tam sim no, thiab cov pa oxygen concentration hauv dej yog xam los ntawm kev ntsuas qhov diffusion tam sim no. Cov txheej txheem tam sim no rau electrochemical sojntsuam txoj kev ntsuas cov pa oxygen yog HJ 509-2009. Cov kab lus no feem ntau tham txog thiab tshuaj xyuas cov haujlwm thiab kev saib xyuas cov ntsiab lus ntawm electrochemical sojntsuam txoj kev ntsuas cov pa oxygen hauv dej, kom nkag siab tag nrho cov yam ntxwv ntawm qhov ntsuas thiab yog li txhim kho qhov ntsuas qhov tseeb ntawm cov ntsuas pa oxygen.


Dissolved oxygen meter range calibration
Laboratory method 1 (saturated air water method): Nyob rau hauv chav tsev kub ntawm 20 degree, sau 1L ntawm ultrapure dej nyob rau hauv ib tug 2L beaker, aerate dej rau 2 teev, nres aeration thiab cia nws sawv ntsug rau 30 feeb, thiab ces ua ntau yam calibration ntawm qhov ntsuas. Xaiv cov hlau nplaum ceev kom yog 500rpm los yog do cov electrode ntau zaus nyob rau hauv cov dej theem pib lub calibration. Xaiv cov huab cua saturated thiab dej calibration ntawm qhov ntsuas interface. Tom qab ua tiav, tag nrho cov nplai yuav tshwm sim li 100%.


Laboratory method 2 (dej-saturated air method): Ntawm chav tsev kub ntawm 20 degree, ntxiv dej rau hauv daim txhuam cev hauv lub tes tsho tiv thaiv kom txog thaum nws ntub tag, nqus cov dej ntawm cov electrode membrane nrog cov ntawv lim. , thiab tom qab ntawd muab cov electrode rov qab rau lub tes tsho tiv thaiv. Tom qab sib npaug hauv lub tes tsho rau 2 teev, pib qhov calibration. Xaiv cov dej-saturated cua calibration ntawm qhov ntsuas interface. Tom qab ua tiav, qhov ntsuas tag nrho yog tshwm sim li 102.3%. Feem ntau hais lus, calibration tau siv cov dej-saturated cua txoj kev thiab cov saturated cua-dej txoj kev yog zoo ib yam. Tom qab calibration, saturated cua-dej los yog dej-saturated cua yog rov qab-kuaj, thiab ntsuas tus nqi yog nyob ib ncig ntawm 9.0mg / L.


Kev ntsuas ntawm qhov chaw: Lub ntsuas yuav tsum tau ntsuas ua ntej txhua qhov kev siv. Nws yog ib qho nyuaj ua nws nyob rau hauv ib puag ncig ntawm 20 degree thaum siv sab nraum zoov. Yog li ntawd, koj tuaj yeem xaiv txoj kev dej-saturated cua los ntsuas hauv lub tes tsho sojntsuam ntawm qhov chaw. Siv txoj kev no los ntsuas qhov ntsuas ntsuas. Qhov kev qhia yuam kev yog nyob rau hauv qhov kev lees paub thiab tuaj yeem siv tau ib txwm.


Zero point calibration
Siv cov dej tshiab uas tau npaj anaerobic, yaj {{0}}}.25g sodium sulfite thiab 0.25g cobalt chloride hexahydrate hauv 250mL ultrapure dej, muab cov sojntsuam mus rau hauv cov dej anaerobic thiab txav nws maj mam, pib lub xoom point calibration, thiab tos kom txog thaum lub ntsuas ntsuas stabilizes. Nyem Ua kom tiav tom qab xoom. Cov cuab yeej nrog xoom taw tes them nyiaj tsis tas yuav ua xoom point calibration.

 

4 Digital oxygen Meter

 

 

Xa kev nug